...
首页> 外文期刊>Journal of Radiation Research: Official Organ of the Japan Radiation Research Society >Correlation between tumor size and blood volume in lung tumors: a prospective study on dual-energy gemstone spectral CT imaging
【24h】

Correlation between tumor size and blood volume in lung tumors: a prospective study on dual-energy gemstone spectral CT imaging

机译:肺肿瘤中肿瘤大小与血容量的相关性:双能宝石光谱CT成像的前瞻性研究

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The purpose of this study was to investigate the relationship between tumor size and blood volume for patients with lung tumors, using dual-energy computed tomography (DECT) and a gemstone spectral imaging (GSI) viewer. During the period from March 2011 to March 2013, 50 patients with 57 medically inoperable lung tumors underwent DECT before stereotactic body radiotherapy (SBRT) of 50–60 Gy in 5–6 fractions. DECT was taken for pretreatment evaluation. The region-of-interest for a given spatial placement of the tumors was set, and averages for CT value, water density and iodine density were compared with tumor size. The average values for iodine density in tumors of ≤2 cm, 2–3 cm, and >3 cm maximum diameter were 24.7, 19.6 and 16.0 (100 μg/cm~3), respectively. The average value of the iodine density was significantly lower in larger tumors. No significant correlation was detected between tumor size and average CT value or between tumor size and average water density. Both the average water density and the average CT value were affected by the amount of air in the tumor, but the average iodine density was not affected by air in the tumor. The average water density and the average CT value were significantly correlated, but the average iodine density and the average CT value showed no significant correlation. The blood volume of tumors can be indicated by the average iodine density more accurately than it can by the average CT value. The average iodine density as assessed by DECT might be a non-invasive and quantitative assessment of the radio-resistance ascribable to the hypoxic cell population in a tumor.
机译:这项研究的目的是使用双能计算机断层扫描(DECT)和宝石光谱成像(GSI)查看器研究肺癌患者的肿瘤大小与血容量之间的关系。在2011年3月至2013年3月期间,对50例患有57种医学上无法手术的肺部肿瘤的患者进行了5-6级立体定向身体放疗(SBRT)50-60 Gy之前的DECT。采取DECT进行预处理评估。设置给定肿瘤位置的关注区域,并将CT值,水密度和碘密度的平均值与肿瘤大小进行比较。最大直径≤2cm,2-3 cm和> 3 cm的肿瘤中碘浓度的平均值分别为24.7、19.6和16.0(100μg/ cm〜3)。在较大的肿瘤中,碘浓度的平均值明显较低。在肿瘤大小与平均CT值之间或在肿瘤大小与平均水密度之间未检测到显着相关性。平均水密度和平均CT值均受肿瘤中空气量的影响,但平均碘密度不受肿瘤中空气的影响。平均水密度与平均CT值呈显着相关,但平均碘密度与平均CT值无显着相关性。通过平均碘浓度比通过平均CT值可以更准确地指示肿瘤的血容量。通过DECT评估的平均碘密度可能是对肿瘤中低氧细胞群所致的抗辐射性的非侵入性和定量评估。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号