PURPOSE: A new axis-marking method, the mapping method, for toric intraocular lens (IOL) implantation is described, and its accuracy is compared with that of conventional methods. METHODS: For toric IOL implantation, the steepest corneal axis was determined by IOLMaster optical biometer measurement (Carl Zeiss Meditec). Three marking methods for accurate alignment of the IOL astigmatism axis to the steepest corneal axis were evaluated and compared. For method 1, the patient was seated at the surgical table and instructed to gaze at a distant target. Using a toric reference marker, the corneal limbus was marked at the 3-, 6-, and 9-o'clock positions. The goal axis was also marked using a toric axis marker. Method 2 used a horizontal slit beam for reference marking points at 3 and 9 o'clock. Method 3 was the new mapping method, in which an anterior segment photograph was used to identify several reference vessel points and axis marking points and to calculate actual lengths from the reference vessel points to the axis marking points. During surgery, the axis marking points were marked on the limbus of the eye using calipers. The accuracy of the three axis-marking methods was evaluated using anterior segment photographs. RESULTS: With method 1, the average axis-marking error was 3.69+/-1.49 degrees . With method 2, the average axis-marking error was 3.14+/-1.64 degrees . With method 3, the new mapping method, the average axis-marking error was 2.29+/-1.06 degrees . The new mapping method was more accurate than methods 1 and 2 (P<.01 and P=.016, respectively, paired t test). Axis-marking errors of the two conventional methods were not significantly different (P=.061). CONCLUSIONS: The new axis-marking method, which uses distinct conjunctival vessels as a reference point, showed less axis-marking error compared to the conventional methods examined in this study.
机译:目的:介绍一种用于复曲面人工晶状体(IOL)植入的新的轴标记方法,即映射方法,并将其准确性与常规方法进行比较。方法:对于复曲面人工晶状体植入,最陡的角膜轴是通过IOLMaster光学生物测量仪(Carl Zeiss Meditec)确定的。评估并比较了三种将IOL散光轴与最陡的角膜轴精确对准的标记方法。对于方法1,将患者坐在手术台上并指示注视远处的目标。使用复曲面参考标记,在3点,6点和9点钟位置标记角膜缘。还使用复曲面轴标记来标记目标轴。方法2在3点和9点使用水平缝隙光束作为参考标记点。方法3是一种新的映射方法,其中使用前眼部照片来识别多个参考血管点和轴标记点,并计算从参考血管点到轴标记点的实际长度。在手术期间,使用卡尺在眼角膜缘上标记轴标记点。使用前段照片评估了三种轴标记方法的准确性。结果:方法1的平均轴标记误差为3.69 +/- 1.49度。使用方法2时,平均轴标记误差为3.14 +/- 1.64度。使用新的映射方法方法3,平均轴标记误差为2.29 +/- 1.06度。新的映射方法比方法1和2更准确(分别为p <.01和P = .016,成对t检验)。两种常规方法的轴标记误差没有显着差异(P = .061)。结论:与本研究中检查的常规方法相比,以独特的结膜血管为参考点的新的轴标记方法显示出较小的轴标记误差。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号