...
首页> 外文期刊>Journal of refractive surgery >Contrast sensitivity and higher order aberrations in eyes implanted with AcrySof IQ SN60WF and AcrySof SN60AT intraocular lenses.
【24h】

Contrast sensitivity and higher order aberrations in eyes implanted with AcrySof IQ SN60WF and AcrySof SN60AT intraocular lenses.

机译:植入AcrySof IQ SN60WF和AcrySof SN60AT人工晶状体的眼睛的对比度敏感性和高阶像差。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: To evaluate the efficacy of the aspheric optic of the AcrySof IQ SN60WF intraocular lens (IOL) in decreasing spherical and total higher order aberrations and improving contrast sensitivity after cataract surgery compared to the spheric AcrySof SN60AT. METHODS: Fifty-two eyes of 36 patients were evaluated at the University of Texas Southwestern Medical Center at Dallas 3 to 6 months after phacoemulsification with implantation of the AcrySof IQ SN60WF (27 eyes) or AcrySof SN60AT (25 eyes) IOL. Eyes with previous surgery or ocular pathology were excluded. RESULTS: Eyes implanted with the AcrySof IQ SN60WF had less total higher order and spherical aberrations than AcrySof SN60AT-implanted eyes at pupils of 4 mm (0.14+/-60.06 vs 0.18+/-0.04 microm and -0.01+/-0.03 vs 0.09+/-0.03 microm, respectively), 5 mm (0.24+/-0.07 vs 0.34+/-0.08 microm and 0.03+/-0.02 vs 0.23+/-0.08 microm, respectively), and 6 mm (0.42+/-0.13 vs 0.67+/-0.12 microm and 0.08+/-0.04 and 0.46+/-0.09 microm, respectively), (P<.05 for all), with similar mean coma, trefoil, and 5th order aberrations. AcrySof SN60WF eyes showed better contrast sensitivity than AcrySof SN60AT eyes at 12 and 18 cycles per degree (cpd) under mesopic conditions (1.65+/-0.23 vs 1.51+/-0.25 and 1.22+/-0.21 vs 1.01+/-0.19, respectively), and at 18 cpd under glare (1.12+/-0.30 vs 0.87+/-0.31, respectively) (P<.05). Photopic contrast sensitivity was similar in both groups. The two groups had comparable mean age, axial length, IOL power, and postoperative mesopic and photopic pupil sizes. CONCLUSIONS: Compared to a spheric optic, the aspheric design of the AcrySof IQ SN60WF reduces spherical aberration, especially under larger pupil sizes, and improves mesopic contrast sensitivity at higher frequencies with and without glare.
机译:目的:与球面AcrySof SN60AT相比,评估AcrySof IQ SN60WF人工晶状体(IOL)的非球面镜片在降低球面像差和总高阶像差以及改善白内障手术后的对比敏感性方面的功效。方法:超声乳化植入AcrySof IQ SN60WF(27眼)或AcrySof SN60AT(25眼)IOL超声乳化后3至6个月,在达拉斯的德克萨斯大学西南医学中心对36例患者的52只眼进行了评估。排除曾接受手术或眼部病理检查的眼睛。结果:在4 mm瞳孔处,植入AcrySof IQ SN60WF的眼睛比植入AcrySof SN60AT的眼睛具有更高的总阶数和球差(0.14 +/- 60.06 vs 0.18 +/- 0.04 microm和-0.01 +/- 0.03 vs 0.09分别为+/- 0.03微米),5毫米(分别为0.24 +/- 0.07与0.34 +/- 0.08微米和0.03 +/- 0.02与0.23 +/- 0.08微米)和6毫米(0.42 +/- 0.13与分别为0.67 +/- 0.12微米和0.08 +/- 0.04和0.46 +/- 0.09微米相比)(所有P均<0.05),具有类似的平均昏迷,三叶形和5阶像差。在介观条件下,每度(cpd)12和18个周期(cpd)时,AcrySof SN60WF眼睛表现出比AcrySof SN60AT眼睛更好的对比度敏感度(分别为1.65 +/- 0.23 vs 1.51 +/- 0.25和1.22 +/- 0.21 vs 1.01 +/- 0.19 ),以及在眩光下18 cpd(分别为1.12 +/- 0.30与0.87 +/- 0.31)(P <.05)。两组的明暗对比敏感度相似。两组平均年龄,眼轴长度,IOL屈光度以及术后中视和明视瞳孔大小均具有可比性。结论:与球面光学器件相比,AcrySof IQ SN60WF的非球面设计减少了球面像差,尤其是在较大的瞳孔尺寸下,并提高了在有和没有眩光的较高频率下的中观对比度灵敏度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号