首页> 外文期刊>Journal of refractive surgery >Repeatability of ocular biomechanical data measurements with a scheimpflug-based noncontact device on normal corneas
【24h】

Repeatability of ocular biomechanical data measurements with a scheimpflug-based noncontact device on normal corneas

机译:基于Scheimpflug的非接触式设备在正常角膜上进行眼生物力学数据测量的可重复性

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Purpose: To analyze the repeatability of a new device measuring ocular biomechanical properties, central corneal thickness (CCT), and intraocular pressure (IOP) and to investigate these parameters and their correlations in healthy eyes. Methods: Three consecutive measurements were performed on each eye using the CorVis ST device (Oculus Optikger?te, Inc., Wetzler, Germany). Ten specific parameters, CCT, and IOP were measured. Biometric data were recorded with IOLMaster (Carl Zeiss Meditec, Jena, Germany). Results: This study comprised 75 eyes of 75 healthy volunteers (mean age: 61.24 ± 15.72 years). Mean IOP was 15.02 ± 2.90 mm Hg and mean CCT was 556.33 ± 33.13 μm. Intraclass correlation coefficient (ICC) was 0.865 for IOP and 0.970 for CCT, and coefficient of variation was 0.069 for IOP and 0.008 for CCT. ICC was 0.758 for maximum amplitude at highest concavity and 0.784 for first applanation time, and less than 0.6 for all other parameters. The device-specific data showed no significant relationship with age and axial length. Flattest and steepest keratometric values and IOP showed a significant correlation with the 10 device-specific parameters. Conclusions: The CorVis ST showed high repeatability for only IOP and pachymetric values. Single measurements are not reliable for the 10 device-specific parameters. The device allows for conducting clinical examinations and screening for surgeries altering ocular biomechanical properties with some form of averaging of multiple measurements.
机译:目的:分析一种测量眼生物力学特性,角膜中央厚度(CCT)和眼内压(IOP)的新设备的可重复性,并研究这些参数及其在健康眼睛中的相关性。方法:使用CorVis ST设备(德国Wetzler的Oculus Optikger?te,Inc)对每只眼睛进行三次连续测量。测量了十个具体参数CCT和IOP。用IOLMaster(Carl Zeiss Meditec,耶拿,德国)记录生物数据。结果:本研究由75名健康志愿者(平均年龄:61.24±15.72岁)的75只眼睛组成。平均IOP为15.02±2.90 mm Hg,平均CCT为556.33±33.13μm。类内相关系数(ICC)IOP为0.865,CCT为0.970,变异系数IOP为0.069,CCT为0.008。最大凹度下最大振幅的ICC为0.758,第一次压平时间的ICC为0.784,所有其他参数的ICC小于0.6。特定于设备的数据显示与年龄和轴向长度无明显关系。最平坦和最陡峭的角膜曲率值和IOP与10个特定于设备的参数具有显着相关性。结论:CorVis ST仅对IOP和测厚法值显示出高重复性。对于10个设备特定的参数,单次测量不可靠。该设备允许进行临床检查和筛查以改变多次测量的平均形式改变眼生物力学特性的手术。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号