首页> 外文期刊>Journal of refractive surgery >Changes in pupil size and centroid shift in eyes with uncomplicated in-the-bag IOL implantation.
【24h】

Changes in pupil size and centroid shift in eyes with uncomplicated in-the-bag IOL implantation.

机译:简易袋内人工晶体植入后,瞳孔大小和质心移位发生改变。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: To determine changes in entrance pupil size and pupil center shift under low mesopic and photopic conditions of illumination in eyes with in-the-bag intraocular lens (IOL) implantation. METHODS: Entrance pupil size and pupil center shift were measured under low mesopic (0.06 lux) and photopic (60 lux) conditions of illumination in 55 patients with unilateral pseudophakia (study group) and 55 age- and sex-matched patients with bilateral cataracts (control group) using the NIDEK OPD-Scan. Pseudophakic eyes had an uncomplicated intraoperative and postoperative course and best spectacle-corrected visual acuity of 20/20. Cataractous eyes had no additional ocular or systemic problems affecting the pupil. Both groups were analyzed with respect to pupil size and shift in both conditions of illumination. RESULTS: Mean patient age was 64.2 +/- 6.8 and 63.6 +/- 4.3 years in the study and control groups, respectively (P = .45). In the study group, differences in pupil size under low mesopic (5.12 +/- 1.02and 5.13 +/- 0.96 mm for pseudophakic and phakic eyes, respectively) and photopic (3.44 +/- 0.39 and 3.45 +/- 0.39 mm for pseudophakic and phakic eyes, respectively) conditions of illumination were not statistically significant (P = 1.00 and P = .95 for pseudophakic and phakic eyes, respectively). Differences in pupil shift between pseudophakic (0.11 +/- 0.08 mm) and phakic (0.12 +/- 0.10 mm) eyes were not statistically significant (P = .83) in the study group. In the control group, differences in pupil size under low mesopic (P = .59) and photopic conditions of illumination (P = .60) in the right and left eyes as well as pupil shift (P = .71) were not statistically significant. CONCLUSIONS: Uncomplicated in-the-bag IOL implantation has no influence on pupil size and shift.
机译:目的:确定在袋装人工晶状体(IOL)植入的眼睛在低中视和近视照明条件下入射瞳孔大小和瞳孔中心偏移的变化。方法:在55例单侧假晶状体患者(研究组)和55例年龄和性别相匹配的双侧白内障患者中,在低中视(0.06 lux)和明视(60 lux)照明条件下测量入瞳大小和瞳孔中心偏移(对照组)使用NIDEK OPD-Scan。伪晶状体眼的术中和术后病程不复杂,并且眼镜矫正的最佳视力为20/20。白内障眼睛没有影响瞳孔的其他眼部或全身性问题。对两组的瞳孔大小和两种照明条件下的偏移进行了分析。结果:研究组和对照组的平均患者年龄分别为64.2 +/- 6.8岁和63.6 +/- 4.3岁(P = .45)。在研究组中,低近视(假晶状眼和有晶状眼的分别为5.12 +/- 1.02和5.13 +/- 0.96 mm)和明视(假晶状体为3.44 +/- 0.39和3.45 +/- 0.39 mm)的瞳孔大小差异和分别有晶状体眼)的照明条件在统计学上不显着(假晶状眼和有晶状体眼分别为P = 1.00和P = .95)。在研究组中,假晶状体眼(0.11 +/- 0.08 mm)和晶状体眼(0.12 +/- 0.10 mm)之间的瞳孔移位差异无统计学意义(P = .83)。在对照组中,右眼和左眼的低中视(P = .59)和明视照明条件(P = .60)的瞳孔大小差异以及瞳孔移位(P = .71)均无统计学意义。 。结论:简单的袋内人工晶体植入对瞳孔大小和移位没有影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号