摘要

The limitation in sample size and the choice in parameters for the application of the micro-crystal (MC) model have been tested and discussed. The testing was performed through the fitting of calculated Raman spectra by using the MC model with the observed Raman spectra for nearly uniform-sized nano-crystalline (NC)-Si of smaller than 2 nm. The results showed that the good fittings could not be obtained, if the phonon dispersion curves omega(q) and Raman linewidths Gamma of bulk-crystals (BCs) were used, i.e. if the bulk-like approximation (BLA) was used in the fitting. Moreover, an analysis of the fitting results indicates that when the size of NC-Si is smaller than about 4 nm, the MC model based on -BLA will be invalid. Copyright (C) 2008 John Wiley & Sons, Ltd.
机译:测试和讨论了样本量的限制和微晶(MC)模型应用的参数选择。通过使用MC模型将计算的拉曼光谱与观察到的拉曼光谱进行拟合,对小于2 nm的几乎均匀尺寸的纳米晶体(NC)-Si进行测试。结果表明,如果使用声子色散曲线omega(q)和拉曼线宽γ的块状晶体(BCs),即如果使用块状近似(BLA)拟合,将无法获得良好的拟合。 。此外,对拟合结果的分析表明,当NC-Si的尺寸小于约4 nm时,基于-BLA的MC模型将无效。版权所有(C)2008 John Wiley&Sons,Ltd.