首页> 外文期刊>Journal of liquid chromatography and related technologies >RP-HPLC method for simultaneous determination of thiobenzanilide and its oxidation products: Monitoring the oxidation of thiobenzanilide with Jones' reagent
【24h】

RP-HPLC method for simultaneous determination of thiobenzanilide and its oxidation products: Monitoring the oxidation of thiobenzanilide with Jones' reagent

机译:RP-HPLC法同时测定硫代苯甲酰苯胺及其氧化产物:用琼斯试剂监测硫代苯甲酰苯胺的氧化

获取原文
获取原文并翻译 | 示例
           

摘要

The reaction of thiobenzanilide with various oxidants leads to the formation of a few possible products such as benzanilide, 2-phenylbenzothiazole, thiobenzanilide-S-oxide, bis(N-phenylbenzimidoyl) disulfide, and bis(N-phenylbenzimidoyl) sulfide. The formation of these products depends on the reaction conditions and liquid chromatography is a convenient method for monitoring the oxidation reaction. In the present study, a reversed-phase HPLC method is developed for separation and simultaneous determination of thiobenzanilide and its oxidation products using an analytical column Lichrosorb RP18 (250 x 4 mm, particle diameter 5 mu m) and gradient elution with acetonitrile and water with phosphoric acid (pH = 3.0). The elution is monitored in the whole UV range (diode array detector) and detection at 254nm is chosen for all examined analytes, except for thiobenzanilide-S -oxide, for which the wavelength of 344 nm is preferred regarding sensitivity and selectivity. The calibration curves for quantitative determination of thiobenzanilide and its oxidation products were constructed in the concentration range of 2 x 10(-6) mol/ L-1 X 10(-3) mol/L. Linear dependence of the peak area versus concentration of each analyte was established with satisfactory values of the coefficient of correlation (R-2 > 0.99). The proposed method was then applied for monitoring the reaction of oxidation of thiobenzanifide with Cr(VI), the so-called Jones' reagent, and the results are presented and discussed.
机译:硫代苯甲腈与各种氧化剂的反应导致形成一些可能的产物,例如苯甲酰苯胺,2-苯基苯并噻唑,硫代苯甲酰-S-氧化物,双(N-苯基苯甲酰亚胺基)二硫化物和双(N-苯基苯甲酰亚胺基)硫化物。这些产物的形成取决于反应条件,液相色谱法是监测氧化反应的便捷方法。在本研究中,开发了一种反相HPLC方法,用于使用分析柱Lichrosorb RP18(250 x 4 mm,粒径5μm)分离和同时测定硫代苯甲酰苯胺及其氧化产物,并用乙腈和水进行梯度洗脱。磷酸(pH = 3.0)。在整个紫外线范围内监控洗脱(二极管阵列检测器),并为所有检查的分析物选择254nm处的检测,但硫代苯甲酰苯胺-S-氧化物除外,就灵敏度和选择性而言,首选344 nm波长。建立浓度范围为2 x 10(-6)mol / L-1 X 10(-3)mol / L的硫代苯甲酰苯胺及其氧化产物定量校准曲线。峰面积与每种分析物浓度的线性相关性通过相关系数的令人满意的值确定(R-2> 0.99)。然后将所提出的方法用于监测硫代苯并尼菲与所谓的琼斯试剂Cr(VI)的氧化反应,并介绍和讨论了结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号