...
首页> 外文期刊>Journal of prosthodontics: official journal of the American College of Prosthodontists >Comparison of the Marginal Adaptation of Zirconium Dioxide Crowns in Preparations with Two Different Finish Lines
【24h】

Comparison of the Marginal Adaptation of Zirconium Dioxide Crowns in Preparations with Two Different Finish Lines

机译:具有两种不同终点线的制剂中二氧化锆冠的边缘适应性比较

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Purpose: The purpose of this study was to evaluate the marginal adaptation of zirconium dioxide crowns in preparations with two different finish line configurations before and after porcelain firing cycles, after a glaze cycle, and after cementation. Materials and Methods: Twenty human molar teeth were prepared to receive full crowns; ten were prepared with a 90° round shoulder and another ten with a 45° chamfer finish line. Zirconium dioxide copings were fabricated using CAD/CAM technology (Lava? system). They were then veneered with a low-fusing glass-ceramic (IPS e.max? Ceram). Finally, they were glazed and cemented with a resin-composite cement (RelyX? Unicem, Aplicap?). Measurements for marginal adaptation using stereomicroscopy (40×) were performed at four stages: copings (S1), after porcelain firing cycles (S2), after glazing (S3), and after cementation (S4). One-way ANOVA was used to assess the influence of the finish line design on the marginal adaptation in each stage. Two-way ANOVA with repeated measurements was performed to assess the influence on the marginal adaptation of the porcelain firing cycles, glaze firing cycle, and cementation. Results: The measured marginal gap mean values for the shoulder group (μm) were: 50.13 (S1), 54.32 (S2), 55.12 (S3), and 59.83 (S4). The values for the chamfer group were: 63.56 (S1), 71.85 (S2), 74.12 (S3), and 76.97 (S4). When comparing marginal gaps between specimens with two different finish lines, differences were noticed at the four studied stages (p= 0.0165, p= 0.0027, p= 0.0009, and p= 0.0009, respectively). No differences were manifested in the marginal gap measurements of the shoulder group at the different stages of fabrication (p= 0.4335); however, in the chamfer group, differences were noticed between S1 and S3 (p= 0.0042). Conclusions: Marginal adaptation was influenced by the finish line design. The firing cycles significantly affected the chamfer group; nevertheless, the marginal gap was within the range of clinical acceptability.
机译:目的:本研究的目的是评估在烧成前后,釉料循环后和胶结后具有两种不同终点线配置的制品中二氧化锆冠的边缘适应性。材料和方法:准备20颗人类磨牙以容纳全冠;十个带有90°圆角肩部,另外十个带有45°倒角终点线。使用CAD / CAM技术(Lava?系统)制造二氧化锆顶盖。然后用低熔点玻璃陶瓷(IPS e.max?Ceram)贴面。最后,将其上釉并用树脂复合水泥(RelyX?Unicem,Aplicap?)粘接。使用立体显微镜(40倍)对边缘适应性的测量分四个阶段进行:顶盖(S1),烤瓷循环(S2),上釉(S3)和胶结后(S4)。单向方差分析用于评估终点线设计对每个阶段的边际适应的影响。进行了两次重复测量的方差分析(ANOVA),以评估其对瓷烧制循环,釉烧制循环和胶结的边际适应性的影响。结果:肩部组的测得边缘间隙平均值(μm)为:50.13(S1),54.32(S2),55.12(S3)和59.83(S4)。倒角组的值为:63.56(S1),71.85(S2),74.12(S3)和76.97(S4)。当比较具有两条不同终点线的试样之间的边际间隙时,在四个研究阶段发现差异(分别为p = 0.0165,p = 0.0027,p = 0.0009和p = 0.0009)。在制造的不同阶段,肩部组的边缘间隙测量没有差异(p = 0.4335);但是,在倒角组中,S1和S3之间存在差异(p = 0.0042)。结论:边缘适应受终点线设计的影响。发射周期显着影响倒角组。但是,边缘间隙在临床可接受范围内。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号