...
首页> 外文期刊>The Journal of Advanced Prosthodontics >Comparison of the marginal fit of milled yttrium stabilized zirconium dioxide crowns obtained by scanning silicone impressions and by scanning stone replicas
【24h】

Comparison of the marginal fit of milled yttrium stabilized zirconium dioxide crowns obtained by scanning silicone impressions and by scanning stone replicas

机译:通过扫描硅树脂印模和扫描石头复制品获得的经过研磨的钇稳定的二氧化锆冠的边缘拟合的比较

获取原文

摘要

PURPOSE To determine the discrepancy in monolithic zirconium dioxide crowns made with computer-aided design and computer-aided manufacturing (CAD/CAM) systems by comparing scans of silicone impressions and of master casts. MATERIALS AND METHODS From a Cr-Co master die of a first upper left molar, 30 silicone impressions were taken. The 30 silicone impressions were scanned with the laboratory scanner, thus obtaining 30 milled monolithic yttrium stabilized zirconium dioxide (YSZD) crowns (the silicone group). They were poured and the working models were scanned, obtaining 30 milled monolithic yttrium stabilized zirconium dioxide (YSZD) crowns (the plaster group). Three predetermined points were analyzed in each side of the crown (Mesial, Distal ,Vestibular and Palatal), and the marginal fit was evaluated with SEM (×600). The response variable is the discrepancy from the master model. A repeated measures ANOVA with two within subject factors was performed to study significance of main factors and interaction. RESULTS Mean marginal discrepancy was 22.42±35.65 μm in the silicone group and 8.94±14.69 μm in the plaster group. The statistical analysis showed significant differences between the two groups and also among the four aspects. Interaction was also significant ( P =.02). CONCLUSION The mean marginal fit values of the two groups were within the clinically acceptable values. Significant differences were found between the groups according to the aspects studied. Various factors influenced the accuracy of digitizing, such as the design, the geometry, and the preparation guidance, as well as the texture, roughness and the color of the scanned material.
机译:目的通过比较硅树脂印模和母模的扫描,确定由计算机辅助设计和计算机辅助制造(CAD / CAM)系统制成的整体式二氧化锆牙冠的差异。材料和方法从第一个左上磨牙的Cr-Co母模中,取出30个硅树脂印模。用实验室扫描仪扫描了30个有机硅印模,从而获得了30个磨碎的整体钇稳定的二氧化锆(YSZD)冠(有机硅基团)。将它们倒出并扫描工作模型,获得30个磨碎的整体钇稳定二氧化锆(YSZD)冠(石膏组)。在牙冠的每一侧(内侧,远端,前庭和Pala骨)分析三个预定点,并用SEM(×600)评估边缘拟合。响应变量是与主模型的差异。进行重复测量方差分析(ANOVA),其中两个因素在主观因素内,以研究主要因素和相互作用的意义。结果硅树脂组的平均边缘差异为22.42±35.65μm,而石膏组为8.94±14.69μm。统计分析显示两组之间以及四个方面之间存在显着差异。相互作用也很显着(P = .02)。结论两组的平均边缘拟合值均在临床可接受的范围内。根据所研究的方面,发现各组之间存在显着差异。各种因素影响数字化的准确性,例如设计,几何形状和制备指导,以及被扫描材料的​​质地,粗糙度和颜色。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号