首页> 外文期刊>Journal of physiotherapy >The Berg Balance Scale has high intra- and inter-rater reliability but absolute reliability varies across the scale: A systematic review
【24h】

The Berg Balance Scale has high intra- and inter-rater reliability but absolute reliability varies across the scale: A systematic review

机译:Berg Balance量表具有较高的评估者内部和评估者之间的信度,但绝对信度在整个量表中有所不同:系统评价

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Questions: What is the intra-rater and inter-rater relative reliability of the Berg Balance Scale? What is the absolute reliability of the Berg Balance Scale? Does the absolute reliability of the Berg Balance Scale vary across the scale? Design: Systematic review with meta-analysis of reliability studies. Participants: Any clinical population that has undergone assessment with the Berg Balance Scale. Outcome measures: Relative intra-rater reliability, relative inter-rater reliability, and absolute reliability. Results: Eleven studies involving 668 participants were included in the review. The relative intrarater reliability of the Berg Balance Scale was high, with a pooled estimate of 0.98 (95% CI 0.97 to 0.99). Relative inter-rater reliability was also high, with a pooled estimate of 0.97 (95% CI 0.96 to 0.98). A ceiling effect of the Berg Balance Scale was evident for some participants. In the analysis of absolute reliability, all of the relevant studies had an average score of 20 or above on the 0 to 56 point Berg Balance Scale. The absolute reliability across this part of the scale, as measured by the minimal detectable change with 95% confidence, varied between 2.8 points and 6.6 points. The Berg Balance Scale has a higher absolute reliability when close to 56 points due to the ceiling effect. We identified no data that estimated the absolute reliability of the Berg Balance Scale among participants with a mean score below 20 out of 56. Conclusion: The Berg Balance Scale has acceptable reliability, although it might not detect modest, clinically important changes in balance in individual subjects. The review was only able to comment on the absolute reliability of the Berg Balance Scale among people with moderately poor to normal balance. [Downs S, Marquez J, Chiarelli P (2013) The Berg Balance Scale has high intra- and inter-rater reliability but absolute reliability varies across the scale: a systematic review. Journal of Physiotherapy 59: 93-99].
机译:问题:Berg平衡量表的评估者内部和评估者之间的相对可靠性是多少? Berg平衡秤的绝对可靠性是多少? Berg平衡秤的绝对可靠性在整个秤上是否有所不同?设计:系统评价,并进行可靠性研究的荟萃分析。参与者:任何接受过伯格平衡量表评估的临床人群。结果测量:相对内部评估者可靠性,相对内部评估者可靠性和绝对可靠性。结果:包括668名参与者的11项研究被纳入评价。 Berg Balance量表的相对评估者内部信度高,估计合计为0.98(95%CI为0.97至0.99)。相对评定者之间的可靠性也很高,汇总估计值为0.97(95%CI为0.96至0.98)。对于某些参与者来说,伯格平衡量表的上限效应是显而易见的。在绝对可靠性分析中,所有相关研究在0至56点Berg平衡量表上的平均得分为20或以上。通过最小可检测变化(95%置信度)测得的该部分量表的绝对可靠性在2.8点至6.6点之间变化。由于天花板效应,当接近56点时,伯格天平秤具有更高的绝对可靠性。我们没有发现任何数据可以估计平均得分低于56的参与者中的Berg平衡量表的绝对可靠性,满分为56。结论:Berg平衡量表具有可接受的可靠性,尽管它可能无法检测出个体平衡的适度,临床上重要的变化科目。该评论只能评论中度平衡差至正常平衡的人的伯格平衡量表的绝对可靠性。 [Downs S,Marquez J,Chiarelli P(2013)Berg Balance量表具有较高的评级内和评级人间信度,但绝对信度在该表中有所不同:系统综述。物理疗法杂志59:93-99]。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号