首页> 外文期刊>Journal of Periodontology >In vivo validation of a three-dimensional optical method to document volumetric soft tissue changes of the interdental papilla.
【24h】

In vivo validation of a three-dimensional optical method to document volumetric soft tissue changes of the interdental papilla.

机译:三维光学方法的体内验证,以记录齿间乳头的体积软组织变化。

获取原文
获取原文并翻译 | 示例
       

摘要

BACKGROUND: Non-surgical and surgical periodontal treatment may cause volumetric changes in the gingival contour. Many techniques have been suggested to minimize soft tissue shrinkage; however, there is a lack of three-dimensional (3D) quantitative data comparing different treatment approaches. The aim of the present study was to clinically validate an easy-to-use chair-side procedure to document volumetric changes in the interdental papilla region. METHODS: Nine volunteers participated in the study. A thin layer of a flowable composite resin material was applied on a papilla and volumetrically analyzed using the clinical chair-side computer-aided design/computer-aided machining (CAD/CAM) 3D method. To accurately measure the applied volumes, the composite resin volume was also determined using microcomputed tomography (micro-CT) and weight measurements. In addition, inter- and intraexaminer differences were evaluated in the same manner using a dental training unit (phantom head) to simulate clinical conditions. RESULTS: No statistically significant difference was found between the results obtained by micro-CT and the weight measurements. The CAD/CAM 3D method showed a significant underestimation of the composite resin volume (P = 0.0047) compared to micro-CT, although the two methods correlated well (R(2) = 0.991). High accuracy was found when inter- and intraexaminer differences were evaluated, showing a concordance correlation coefficient of 0.99. CONCLUSION: CAD/CAM 3D device and software are an easy-to-use chair-side method to document changes in soft tissues.
机译:背景:非手术和手术的牙周治疗可能会导致牙龈轮廓的体积变化。已经提出了许多技术来最小化软组织的收缩。但是,缺乏比较不同治疗方法的三维(3D)定量数据。本研究的目的是临床验证一种易于使用的椅旁程序,以记录牙间乳头区域的体积变化。方法:9名志愿者参加了该研究。将可流动的复合树脂材料薄层涂在乳头上,并使用临床椅端计算机辅助设计/计算机辅助加工(CAD / CAM)3D方法进行体积分析。为了准确地测量所施加的体积,还使用微计算机断层扫描(micro-CT)和重量测量来确定复合树脂的体积。此外,使用牙科训练单元(幻影头)以相同的方式评估检查者之间和检查者之间的差异,以模拟临床状况。结果:微型计算机断层扫描和重量测量结果之间没有发现统计学上的显着差异。与微型CT相比,CAD / CAM 3D方法显示出复合树脂体积的明显低估(P = 0.0047),尽管两种方法相关性很好(R(2)= 0.991)。评估检查者之间和检查者之间的差异时发现了很高的准确性,其一致性相关系数为0.99。结论:CAD / CAM 3D设备和软件是一种易于使用的椅旁方法,用于记录软组织的变化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号