A high-performance liquid chromatographic method for quantifying four of the most common used hydrophilic whitening agent-glycolic acid (GA), ascorbic acid (AA), arbutin (ART) and Mg ascorbyl phosphate (MAP), has been developed. Isocratic separation was performed using a C18 column with ion-pair agent as mobile phase. The analytes were detected by ultraviolet light absorption at the wavelength of 220 and 240 nm, respectively. Calibration curves were found to be linear in the 8.0-36 mg/ml (GA), 10.0-300 microg/ml (AA and ART), and 5.6-451 microg/ml (MAP). The correlation coefficient of linear regression analysis were with the range 0.9974-0.9997. Recoveries of the four analytes were between 94.8 and 100.1% and the precision of this method was better than 6.9% relative standard deviation (R.S.D.) (n=3). It was found that AA degraded in an aqueous solution. To be sure that AA was stable during the HPLC analysis, all analytes were dissolved in distilled water and these solutions were purged with nitrogen gas to remove oxygen and stored at 25 degrees C. The testing results show that the procedure is rapid, simple, selective method and it is suitable for routine analysis of commercial cosmetics.
机译:已开发出一种高效液相色谱方法,用于量化四种最常用的亲水性增白剂乙醇酸(GA),抗坏血酸(AA),熊果苷(ART)和抗坏血酸镁(MAP)。使用离子对试剂作为流动相的C18色谱柱进行等度分离。通过分别在220和240nm的波长处的紫外线吸收来检测分析物。发现校准曲线在8.0-36 mg / ml(GA),10.0-300 microg / ml(AA和ART)和5.6-451 microg / ml(MAP)中呈线性。线性回归分析的相关系数在0.9974-0.9997的范围内。四种分析物的回收率在94.8%至100.1%之间,该方法的精密度优于6.9%相对标准偏差(R.S.D.)(n = 3)。发现AA在水溶液中降解。为了确保AA在HPLC分析过程中稳定,将所有分析物溶解在蒸馏水中,并用氮气吹扫这些溶液以除去氧气,然后将其保存在25摄氏度下。测试结果表明,该过程快速,简单,选择性高方法,适用于商业化妆品的常规分析。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号