摘要

A simple high-performance liquid chromatographic method was developed for the determination of omeprazole in human plasma. Omeprazole and the internal standard, chloramphenicol, were extracted from alkalinized plasma samples using dichloromethane. The mobile phase was 0.05 M Na2HPO4-ACN (65:35, v/v) adjusted to pH 6.5. Analysis was run at a flow rate of 1.0 ml/min at a detection wavelength of 302 nm. The method was specific and sensitive with a detection limit of 2.5 ng/ml at a signal-to-noise ratio of 4:1. The limit of quantification was set at 5 ng/ml. The calibration curve was linear over a concentration range of 5-1280 ng/ml. Mean recovery value of the extraction procedure was about 96%, while the within and between day coefficient of variation and percent error values of the assay method were all less than 14%.
机译:开发了一种简单的高效液相色谱法,用于测定人血浆中的奥美拉唑。使用二氯甲烷从碱化血浆样品中提取奥美拉唑和内标氯霉素。流动相为0.05 M Na2HPO4-ACN(65:35,v / v),调节至pH 6.5。在1.0 nm / min的流速下以302 nm的检测波长进行分析。该方法特异且灵敏,检测限为2.5 ng / ml,信噪比为4:1。定量限设定为5 ng / ml。校准曲线在5-1280 ng / ml的浓度范围内是线性的。提取过程的平均回收率约为96%,而日内和日间变异系数和测定方法的误差百分比均小于14%。