首页> 外文期刊>Journal of Pharmaceutical and Biomedical Analysis: An International Journal on All Drug-Related Topics in Pharmaceutical, Biomedical and Clinical Analysis >Characterization of semi-solid Self-Emulsifying Drug Delivery Systems (SEDDS) of atorvastatin calcium by Raman image spectroscopy and chemometrics
【24h】

Characterization of semi-solid Self-Emulsifying Drug Delivery Systems (SEDDS) of atorvastatin calcium by Raman image spectroscopy and chemometrics

机译:通过拉曼光谱和化学计量学表征阿托伐他汀钙的半固体自乳化药物递送系统(SEDDS)

获取原文
获取原文并翻译 | 示例
           

摘要

A methodology based on Raman image spectroscopy and chemometrics for homogeneity evaluation of formulations containing atorvastatin calcium in Gelucire (R) 44/14 is presented. In the first part of the work, formulations with high amounts of Gelucire (R) 44/14 (80%) and solvents of different polarities (diethylene glycol monoethyl ether, propyleneglycol, propylene glycol monocaprylate and glyceryl mono/dicaprylate/caprate) were prepared for miscibility screening evaluation by classical least squares (CLS). It was observed that Gelucire (R) 44/14 presented higher affinity for the lipophilic solvents glyceryl mono/dicaprylate/caprate and propylene glycol monocaprylate, whose samples were observed to be homogeneous, and lower affinity for the hydrophilic solvents diethylene glycol monoethyl ether and propyleneglycol, whose samples were heterogeneous. In the second part of the work, the ratio of glyceryl mono/dicaprylate/caprate and Gelucire (R) 44/14 was determined based on studies in water and allowed the selection of the proportions of these two excipients in the preconcentrate that provided supersaturation of atorvastatin upon dilution. The preconcentrate was then evaluated for homogeneity by partial least squares (PLS) and an excellent miscibility was observed in this proportion as well. Therefore, it was possible to select a formulation that presented simultaneously homogeneous preconcentrate and solubility enhancement in water by Raman image spectroscopy and chemometrics. (C) 2012 Elsevier B.V. All rights reserved.
机译:提出了一种基于拉曼图像光谱学和化学计量学的方法,用于评估Gelucire(R)44/14中含有阿托伐他汀钙的制剂的均质性。在工作的第一部分中,制备了含有大量Gelucire(R)44/14(80%)和不同极性溶剂(二甘醇单乙醚,丙二醇,丙二醇单辛酸酯和甘油基单/二辛酸酯/癸酸酯)的配方。通过经典最小二乘(CLS)进行混溶性筛选评估。观察到Gelucire(R)44/14对亲脂性溶剂甘油单/二辛酸酯/癸酸酯和丙二醇单辛酸酯具有更高的亲和力,观察到它们的样品是均质的,而对亲水性溶剂二甘醇单乙醚和丙二醇的亲和力较低。 ,其样本是异构的。在工作的第二部分中,基于水的研究确定了甘油单/二辛酸酯/癸酸酯和Gelucire(R)44/14的比例,并允许选择能提供过饱和的预浓缩物中这两种赋形剂的比例。稀释后的阿托伐他汀。然后通过偏最小二乘(PLS)评估预浓缩液的均质性,并且在该比例下也观察到优异的混溶性。因此,有可能选择通过拉曼光谱和化学计量学同时呈现均匀的预浓缩物和在水中的溶解度提高的制剂。 (C)2012 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号