We describe a simple technique for fracture-dislocations of the proximal interphalangeal joint. Eight fingers with a fracture-dislocation were treated with a self-manufactured dynamic external fixator, allowing early mobilization. The fixator consists of pins and rubbers. The clinical and radiographic outcome was evaluated and recorded. A near-normal function was obtained in four patients. The average total active motion was 82 degrees. Radiographic reduction was maintained. This external fixator is an inexpensive and simple technique for these difficult fracture-dislocations. Early intervention (before two weeks post-trauma) is recommended.
机译:我们描述了一种用于近端指间关节骨折脱位的简单技术。使用自行制造的动态外固定架治疗八个具有骨折脱位的手指,从而可以早期动员。固定器由销钉和橡胶组成。评估并记录临床和影像学结果。四名患者获得了接近正常的功能。平均总主动运动为82度。放射线检查得以维持。对于这些困难的骨折脱位,这种外固定器是一种廉价且简单的技术。建议尽早介入(创伤后两周之前)。