Aim: To evaluate the role of electronic faucets in a newborn intensive care unit during a Pseudomonas aeruginosa outbreak. Methods: After three patients had P. aeruginosa bacteremia, environmental cultures including those from patient rooms, incubator, ventilators, total parenteral nutrition solutions, disinfection solutions, electronic and hand-operated faucet filters/water samples after removing filters and staff hands were taken. Results: Only filters of electronic faucets and water samples after removing filters and one liquid hand soap showed P. aeruginosa (3-7 × 106 cfu/mL). We have removed the electronic faucets and new elbow-operated faucets were installed. Pulsed-field gel electrophoresis analysis of outbreak-blood culture isolates from two patients and isolates from electronic water faucets/one liquid hand soap indicated the presence of 90.7% genetically related subtype, probably from the same clone. Water cultures from new faucets were all clean after installation and after 7 months. Conclusion: We suggest that electronic faucets may be considered a potential risk for P. aeruginosa in hospitals, especially in high-risk units.
机译:目的:评估铜绿假单胞菌爆发期间电子水龙头在新生儿重症监护病房中的作用。方法:三名患者出现铜绿假单胞菌菌血症后,进行环境培养,包括病房,培养箱,通风机,肠胃外营养液,消毒液,取下过滤器和员工手后的电子和手动水龙头过滤器/水样。结果:除去过滤器和一种液体洗手液后,只有电子水龙头和水样的过滤器显示出铜绿假单胞菌(3-7×106 cfu / mL)。我们已经卸下了电子水龙头,并安装了新的肘式水龙头。对来自两名患者和电子水龙头/一种液体洗手液的暴发性血液分离株的脉冲场凝胶电泳分析表明存在90.7%的遗传相关亚型,可能来自同一克隆。新水龙头的水培养在安装后和7个月后全部干净。结论:我们建议在医院中,尤其是在高危人群中,电子水龙头可能被认为是铜绿假单胞菌的潜在风险。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号