首页> 外文期刊>Journal of occupational and environmental hygiene >Exposure data from multi-application, multi-industry maintenance of surfaces and joints sealed with asbestos-containing gaskets and packing.
【24h】

Exposure data from multi-application, multi-industry maintenance of surfaces and joints sealed with asbestos-containing gaskets and packing.

机译:来自用多用途,多行业维护的表面和接头的接触数据,这些接触面和接头用含石棉的垫片和填料密封。

获取原文
获取原文并翻译 | 示例
           

摘要

Fluid sealing devices (gaskets and packing) containing asbestos are manufactured and blended with binders such that the asbestos fibers are locked in a matrix that limits the potential for fiber release. Occasionally, fluid sealing devices fail and need to be replaced or are removed during preventive maintenance activities. This is the first study known to pool over a decade's worth of exposure assessments involving fluid sealing devices used in a variety of applications. Twenty-one assessments of work activities and air monitoring were performed under conditions with no mechanical ventilation and work scenarios described as "worst-case" conditions. Frequently, the work was conducted using aggressive techniques, along with dry removal practices. Personal and area samples were collected and analyzed in accordance with the National Institute for Occupational Safety and Health Methods 7400 and 7402. A total of 782 samples were analyzed by phase contrast microscopy, and 499 samples were analyzed by transmission electron microscopy. The statistical data analysis focused on the overall data sets which were personal full-shift time-weighted average (TWA) exposures, personal 30-min exposures, and area full-shift TWA values. Each data set contains three estimates of exposure: (1) total fibers; (2) asbestos fibers only but substituting a value of 0.0035 f/cc for censored data; and (3) asbestos fibers only but substituting the limit of quantification value for censored data. Censored data in the various data sets ranged from 7% to just over 95%. Because all the data sets were censored, the geometric mean and geometric standard deviation were estimated using the maximum likelihood estimation method. Nonparametric, Kaplan-Meier, and lognormal statistics were applied and found to be consistent and reinforcing. All three sets of statistics suggest that the mean and median exposures were less than 25% of 0.1 f/cc 8-hr TWA sample or 1.0 f/cc 30-min samples, and that there is at least 95% confidence that the true 95th percentile exposures are less than 0.1 f/cc as an 8-hr TWA.
机译:制造包含石棉的流体密封装置(垫片和填料),并将其与粘合剂混合,以使石棉纤维被锁定在基质中,从而限制了纤维释放的可能性。有时,在预防性维护活动期间,流体密封装置会发生故障,需要更换或卸下。这是第一项已知的研究,该研究汇集了十多年来涉及各种应用中的流体密封装置的暴露评估。在没有机械通风的条件下,对工作活动和空气监测进行了21次评估,工作场景被描述为“最坏情况”。通常,这项工作是使用侵略性技术以及干法去除实践进行的。根据美国国家职业安全与卫生研究所7400和7402收集和分析个人和区域样本。相差显微镜对782个样本进行分析,透射电子显微镜对499个样本进行了分析。统计数据分析集中于总体数据集,这些数据集是个人全班时间加权平均(TWA)暴露,个人30分钟暴露和区域全班TWA值。每个数据集包含三个暴露评估:(1)总纤维; (2)仅使用石棉纤维,但用0.0035 f / cc的值代替检查数据; (3)仅使用石棉纤维,但用量化值的下限代替审查数据。各种数据集中的审查数据范围从7%到刚超过95%。因为所有数据集都经过审查,所以使用最大似然估计方法估计了几何均值和几何标准差。应用了非参数统计,Kaplan-Meier统计和对数正态统计,发现它们是一致的且具有补充性。所有这三组统计数据均表明,平均暴露量和中值暴露量少于0.1 f / cc 8小时TWA样品或1.0 f / cc 30分钟样品的25%,并且至少有95%的信心认为真实的第95位在8小时的TWA中,百分位数的曝光量小于0.1 f / cc。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号