It has been reported by previous studies [1-7] that droplet size in a Pease-Anthony Venturi scrubber depends on the jet atomization conditions, such as jet velocity and gas velocity. The assumption of this paper is that actual collector-droplet size in a confined tube such as the Venturi scrubber also depends significantly on preferential droplet deposition on the tube walls, which remove preferentially droplets of a certain size from the core, modifying the mean droplet size of the remaining droplets. To account for this effect, the present study is focused on the experimental measurement of the liquid deposition on the walls of a Pease-Anthony Venturi scrubber and the droplet size remaining in the core. The experiments were carried out varying jet penetration and the number of the injection orifices. A correlation, using dimensionless numbers, was proposed to quantify the influence of each experimental condition. The results showed that liquid deposition has a significant influence in actual collector-droplet size inside a Venturi scrubber.
机译:以前的研究报道[1-7],Pease-Anthony Venturi洗涤塔中的液滴尺寸取决于喷射雾化条件,例如喷射速度和气体速度。本文的假设是,密闭管(例如文丘里管洗涤器)中的实际收集器液滴尺寸还很大程度上取决于管壁上的优先液滴沉积,后者优先从岩心中除去一定尺寸的液滴,从而改变了平均液滴尺寸剩余的液滴。为了解决这个问题,本研究着重于对Pease-Anthony Venturi洗涤塔壁上的液体沉积以及保留在岩心中的液滴尺寸的实验测量。实验是通过改变射流穿透力和注入孔的数量来进行的。提出了使用无量纲数的相关性,以量化每种实验条件的影响。结果表明,液体沉积对文丘里洗涤器内部的实际收集器液滴尺寸有重大影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号