We report an experimental and theoretical study on the alignment error tolerance of a 2 μm-size solid immersion lens (SIL) illuminated by different types of focused spots. Tightly confined focal spots are of great interest for improving the performance of many optical systems, so that a study on the alignment tolerance is of interest. In particular, it was found that micro-SILs can be largely misaligned with respect to the optical axis of an objective lens focusing light onto it and yet allow for a reasonably good immersed spot. In fact, a displacement of approximately 400 nm, i.e. one fifth of the lens diameter, is tolerable. The measurements are compared with a rigorous finite element method model for a micro-SIL, showing an excellent agreement.
机译:我们报告了对2μm尺寸的固体浸没透镜(SIL)的对准误差容限的实验和理论研究,该透镜被不同类型的聚焦点照亮。紧密限制的焦点对于改善许多光学系统的性能非常重要,因此对对准公差的研究也很重要。特别地,发现微SIL相对于将光聚焦在其上的物镜的光轴可能在很大程度上未对准,但仍允许相当好的浸没点。实际上,可以容许大约400nm的位移,即透镜直径的五分之一。将测量结果与用于微型SIL的严格的有限元方法模型进行比较,显示出极好的一致性。