首页> 外文期刊>Journal of neurosurgery. >Biodegradable semirigid plate and miniscrew fixation compared with rigid titanium fixation in experimental calvarial osteotomy.
【24h】

Biodegradable semirigid plate and miniscrew fixation compared with rigid titanium fixation in experimental calvarial osteotomy.

机译:在实验颅骨截骨术中,可生物降解的半刚性板和微型螺钉固定与刚性钛固定相比。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECT: To determine the biocompatibility and suitability of resorbable plates and miniscrews, consolidation of symmetrical, bilateral frontal bone craniotomies that had been closed using various methods was studied in 20 growing lambs. METHODS: Bone fixation with a flexible, punched polylactide plate and four slowly degradable, self-reinforced poly-levolactide (SR-PLLA) or rapidly degradable, self-reinforced polyglycolide (SR-PGA) miniscrews (10 animals in each group) was compared intraindividually with rigid fixation by using a titanium miniplate and four miniscrews. Plain x-ray films, magnetic resonance images, histological studies, and histomorphometric studies were obtained at 4 to 104 weeks. CONCLUSIONS: No dislocation, instability, clinical foreign body reactions, infections, or loss of fixation were observed. Bone consolidation of the 2.35-mm-wide craniotomy lines was incomplete; connective tissue-filled defects through the bone were observed in 13 of 28 lines at 26 to 52 weeks. Statistical analyses based on histomorphometric studies showed no difference in consolidation with SR-PLLA miniscrew and titanium plate/screw fixation or between the two resorbable fixation methods. Fixation with rapidly degradable SR-PGA miniscrews resulted in less effective consolidation than on the contralateral titanium-treated side (p<0.05), but the bone segment was thicker (p<0.005). The SR-PGA miniscrews had disappeared by 6 weeks, the polyactide plate by 104 weeks, and the SR-PLLA miniscrews had been mostly resorbed at 104 weeks. Passive translocation of the titanium plates and screws into the bone tissue was seen at 52 and 104 weeks. In rapidly growing lamb frontal bone, comparable consolidation results, without complications, can be achieved with semi-rigid resorbable fixation compared with rigid metallic fixation.
机译:目的:为确定可吸收板和微型螺钉的生物相容性和适用性,在20只生长中的羔羊中研究了采用各种方法封闭的对称的双侧额骨开颅手术的巩固性。方法:比较了用柔性穿孔聚乳酸板和四个可缓慢降解,自增强的聚丙交酯(SR-PLLA)或可快速降解,自增强的聚乙交酯(SR-PGA)微型螺钉进行骨固定的方法(每组10只动物)使用钛制微型平板和四个微型螺钉分别固定固定。在4至104周时获得了平片X射线胶片,磁共振图像,组织学研究和组织形态学研究。结论:未观察到脱位,不稳定,临床异物反应,感染或固定丧失。 2.35毫米宽的颅骨切开线的骨固位不完全;在26至52周时,在28条线中的13条中观察到了穿过骨头的结缔组织填充缺损。根据组织形态学研究的统计分析表明,使用SR-PLLA微型螺钉和钛板/螺钉固定或两种可吸收固定方法在固结方面没有差异。与对侧经钛处理的一侧相比,用可快速降解的SR-PGA小螺钉进行固定导致的固结效果较差(p <0.05),但骨段较厚(p <0.005)。 SR-PGA微型螺钉消失了6周,聚丙交酯板消失了104周,而SR-PLLA微型螺钉在104周时已被大部分吸收。在第52和104周时观察到钛板和螺钉被动移位到骨组织中。在快速生长的羔羊额骨中,与刚性金属固定相比,半刚性可吸收固定可实现无可比拟的固结效果,而无并发症。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号