Scrubbers are being widely used to remove the dust, sulphur dioxide and other harmful gases from coal-fired boilers. In this paper, a novel 'wet-type' desulphurization absorber, the PCF device (Chinese LOGO), was developed and studied through an experimental method. The mixture of air and SO2 was used as simulated flue gas and CaCO3-in-water suspension was used as absorbent. The results show that the PCF device has a good overall performance for FGD. Under moderate conditions employed, the content of SO2 in outlet flue gas can achieve a level much lower than that permitted, while the pressure drop is very small due to co-flows in preliminarily treating chamber and no venturi structure in inlet tube. Guide plates and self-excitation chamber can improve the SO2 removal efficiency by intensifying the mass-transfer and second purification. Some feasible process parameters are as follows: slurry pH value = 5.6-6.0, liquid-gas ratio = 8.7-10.4L/m~3, superficial gas velocity in inner cylinder = 3.5-4.5 m/s, and addition of Cl~- (in the form of CaCl2) to the slurry (25 g/L) decreased the degree of SO2 removal about 13.12%.
机译:洗涤塔被广泛用于去除燃煤锅炉中的灰尘,二氧化硫和其他有害气体。本文研究了一种新型的“湿式”脱硫吸收剂PCF装置(中文LOGO),并通过实验方法进行了研究。空气和SO2的混合物用作模拟烟道气,CaCO3的水悬浮液用作吸收剂。结果表明,PCF器件在烟气脱硫方面具有良好的整体性能。在适当的条件下,出口烟道气中的SO2含量可以达到比允许水平低得多的水平,而压降由于在初步处理室中的共流作用以及入口管中没有文丘里管结构而非常小。导板和自激腔可以通过加强传质和二次纯化来提高SO2去除效率。一些可行的工艺参数如下:浆液pH值= 5.6-6.0,液气比= 8.7-10.4L / m〜3,内筒表观气速= 3.5-4.5 m / s,添加Cl〜- (以CaCl2的形式)到浆液(25 g / L)中,SO2去除率降低了约13.12%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号