Iatrogenic uterine rupture caused by overinflation of RUMI manipulator balloon.

机译:RUMI机械手球囊过度充气引起的医源性子宫破裂。

获取原文
获取原文并翻译 | 示例
       

摘要

The RUMI uterine manipulator is a useful device for uterine mobilization and chromopertubation during laparoscopic surgery. We report two cases of iatrogenic uterine rupture caused by overinflation of the intrauterine balloon of the RUMI manipulator during chromopertubation. One rupture, which occurred on the uterine fundus, simply was sutured during surgery. The other rupture, which occurred into the uterine lateral wall, caused retroperitoneal hematoma. A second operation was required to treat this complication. Overinflation of the tip balloon of the RUMI manipulator during chromopertubation can cause uterine rupture that can result in massive hematoma.
机译:RUMI子宫操纵器是在腹腔镜手术期间用于子宫动员和色谱操作的有用设备。我们报告了两例因输尿管结扎术期间RUMI机械手的子宫内球囊过度充气引起的医源性子宫破裂。仅在手术过程中缝合了发生在子宫底的一个破裂处。另一个破裂发生在子宫侧壁,引起腹膜后血肿。需要第二次手术来治疗这种并发症。在输精管结扎术期间,RUMI机械手的尖端球囊过度充气会导致子宫破裂,从而导致大量血肿。