首页> 外文期刊>Journal of Microbiological Methods >Comparison of enzyme-linked immunomagnetic chemiluminescence with U.S. Food and Drug Administration's Bacteriological Analytical Manual method for the detection of Escherichia coli O157:H7
【24h】

Comparison of enzyme-linked immunomagnetic chemiluminescence with U.S. Food and Drug Administration's Bacteriological Analytical Manual method for the detection of Escherichia coli O157:H7

机译:酶联免疫磁化学发光法与美国食品药品监督管理局《细菌学分析手册》方法检测大肠杆菌O157:H7的比较

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Escherichia coli O157:H7, a major foodborne pathogen, has been associated with numerous cases of foodborne illnesses. Rapid methods have been developed for the screening of this pathogen in foods in order to circumvent timely plate culture techniques. Unfortunately, many rapid methods are presumptive and do not claim to confirm the presence of E. coli O157:H7. The previously developed method, enzyme-linked immunomagnetic chemiluminescence (ELIMCL), has been improved upon to allow for fewer incidences of false positives when used to detect E. coli O157:H7 in the presence of mixed cultures. The key feature of this assay is that it combines the highly selective synergism of both anti-O157 and anti-H7 antibodies in the sandwich immunoassay format. This work presents application of a newly semi-automated version of ELIMCL to the detection of E. coli O157:H7 in pristine buffered saline yielding detection limits of approximately 1 x 10(5) to 1 x 10(6) of live cells/mL. ELIMCL was further demonstrated to detect E. coli O157:H7 inoculated into artificially contaminated ground beef at ca. 400 CFU/g after a 5 h enrichment and about 1.5 h assay time for a total detection time of about 6.5 h. Finally, ELIMCL was compared with USFDA's Bacteriological Analytical Manual method for E. coli O157:H7 in a double-blind study. Using McNemar's treatment, the two methods were determined to be statistically similar for the detection of E. coli O157:H7 in ground beef inoculated with mixed cultures of select bacteria.
机译:大肠杆菌O157:H7是一种主要的食源性病原体,已与许多食源性疾病病例相关。为了规避及时的平板培养技术,已经开发了用于筛选食品中这种病原体的快速方法。不幸的是,许多快速方法是推定性的,并不能声称证实了O157:H7大肠杆菌。以前开发的酶联免疫磁化学发光(ELIMCL)方法已得到改进,在混合培养物存在下用于检测大肠杆菌O157:H7时,假阳性的发生率更低。该测定法的关键特征是它以三明治免疫测定法形式结合了抗O157和抗H7抗体的高度选择性协同作用。这项工作提出了一种新的半自动化版本的ELIMCL在原始缓冲盐水中检测大肠杆菌O157:H7的应用,产生的检测下限约为活细胞/ mL的1 x 10(5)至1 x 10(6) 。进一步证明,ELIMCL可检测到大约50摄氏度时接种到人工污染的碎牛肉中的大肠杆菌O157:H7。在5 h富集和约1.5 h测定时间后为400 CFU / g,总检测时间约为6.5 h。最后,在一项双盲研究中,将ELIMCL与USFDA的大肠杆菌O157:H7细菌分析手册方法进行了比较。使用McNemar的处理,这两种方法被确定在统计学上相似,用于检测接种了特定细菌混合培养物的碎牛肉中的O157:H7大肠杆菌。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号