Fatigue performance of tibial tray in total knee arthroplasty (TKA) is of critical importance in terms of longevity of the prosthesis. Standards have been proposed by American Society for Testing and Materials (ASTM) and International Organization for Standardization (ISO) to ensure its long-term structural integrity. The aim of the current study is to evaluate the effect of modularity in the tibial tray following the testing standards, using finite element analysis. Goodman and Sines criteria were used to compare the fatigue safety factor (FSF) of four modular designs versus the two conventional designs. Cruciate-retaining (CR) type modular tibial tray designs were better than posterior-stabilized (PS) type tibial tray designs. More cutouts in the tray and absence of keel were reasons for poor fatigue performance.
机译:就假体的寿命而言,胫骨托在全膝关节置换术(TKA)中的疲劳性能至关重要。美国测试和材料学会(ASTM)和国际标准化组织(ISO)已提出标准,以确保其长期结构完整性。本研究的目的是使用有限元分析方法,按照测试标准评估胫骨托中模块性的影响。使用Goodman和Sines标准比较四个模块化设计与两个常规设计的疲劳安全系数(FSF)。十字形保持(CR)型胫骨托设计优于后稳定(PS)型胫骨托设计。托盘中的更多切口和龙骨缺失是造成疲劳性能差的原因。