In this study, moisture diffusion coefficient of a LiCl-impregnated paper membrane was experimentally obtained through an analysis of heat and moisture transfer of an enthalpy exchanger made with the membrane. A sorption curve was separately obtained by a weighing method. Tests were conducted as a function of relative humidity and temperature. Diffusion coefficient first increases up to 60% relative humidity and then decreases. It also increases with the increase of temperature. The variation of the diffusion coefficient is in the range of 1.8 × 10~(-11) m~2/s to 6.0 × 10~(-11) m~2/s, which is smaller than reported values of hydrophilic polymers. The variation of the moisture permeability, however, is in the range of 2.4 × 10~(-7) kg/ms to 1.2 × 10~(-6) kg/ms, which is comparable with reported values of hydrophilic polymers. Thus, similar moisture transfer performance is expected between LiCl-impregnated paper and polymer enthalpy exchangers. Possible explanation on the behavior of the diffusion coefficient with relative humidity is provided.
机译:在这项研究中,通过分析用该膜制成的焓交换器的热和水分传递,实验获得了浸渍LiCl的纸膜的水分扩散系数。通过称重法分别获得吸附曲线。根据相对湿度和温度进行测试。扩散系数首先增加至60%相对湿度,然后降低。它也随着温度的升高而增加。扩散系数的变化范围为1.8×10〜(-11)m〜2 / s至6.0×10〜(-11)m〜2 / s,小于亲水性聚合物的报道值。然而,透湿性的变化在2.4×10〜(-7)kg / ms至1.2×10〜(-6)kg / ms的范围内,与亲水性聚合物的报道值相当。因此,期望在浸渍了LiCl的纸和聚合物焓交换器之间具有相似的水分传递性能。提供了有关相对湿度下扩散系数特性的解释。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号