首页> 外文期刊>Journal of Hand Surgery. American Volume >Radial nerve injury during double plating of a displaced intercondylar fracture
【24h】

Radial nerve injury during double plating of a displaced intercondylar fracture

机译:plating突间骨折双钢板plating神经损伤

获取原文
获取原文并翻译 | 示例
           

摘要

Double-plate fixation is a popular treatment method for intercondylar humeral fractures. Ulnar nerve complications are emphasized, but radial nerve complications are rarely mentioned. We present a case of iatrogenic radial nerve palsy following open reduction and double plating of a supracondylar/ intercondylar fracture of the humerus. Before surgery, only a sensory deficit in the radial nerve territory was present, but after surgery, there was a complete motor deficit of the wrist and finger extensors. On exploration, a segment of nerve was found crushed within the reduced lateral condyle fracture site, with a screw from the posteroradial plate going through the nerve. Although rare, radial nerve injury can occur with posteriorly displaced supracondylar/ intercondylar humerus fractures. When preoperative signs of radial nerve injury are present, we recommend that the radial nerve be identified and protected during double-plate fixation.
机译:双板固定是con间肱骨骨折的一种流行治疗方法。强调尺神经并发症,但很少提及radial神经并发症。我们提出了一个开放性复位和肱骨a上/ con间间骨折的双钢板治疗后的医源性radial神经麻痹的病例。手术前,the神经区域仅存在感觉缺陷,但手术后,腕部和手指伸肌完全运动不足。在探查中,发现神经节段被压在缩小的外侧con突骨折部位,后radi骨板上的螺钉穿过神经。 rare后上con / con间肱骨骨折可发生radial神经损伤,虽然很少见。如果术前出现of神经损伤的迹象,我们建议在双板固定术中识别并保护the神经。