PURPOSE: To evaluate specific fluoroscopic views for assessment of intra-articular screw placement during locked volar plating of the distal radius. METHODS: The distal radius of a cadaver forearm was plated with a fixed-angle volar plate according to the surgical technique guide of the manufacturer. A goniometer was used to place the specimen at various described angles in the fluoroscope including standard posteroanterior (PA), tilt PA (11 degrees ), standard lateral, and tilt lateral (15 degrees , 23 degrees , 30 degrees ) views. Radiographic images of each screw individually and in various combinations were digitally captured. RESULTS: Only the tilt PA view correctly showed all 4 screws to be extra-articular. On the standard PA view, the 2 ulnar screws appeared intra-articular. Lower angle tilt lateral views (15 degrees and 23 degrees ) correctly visualized the ulnar screws but not the styloid screw. The highest angle lateral view (30 degrees ) correctly visualized the radial screws but not the sigmoid (most ulnar) screw. The styloid screw appeared to be intra-articular on every lateral view except at 30 degrees and was correctly visualized on both the PA and tilt PA views. CONCLUSIONS: Multiple oblique views are required for evaluation of intra-articular screw placement during locked volar plating of the distal radius. Lower angle tilt lateral views are more specific for the ulnar screws, and higher angle views are more specific for the radial screws. We suggest first placing the ulnar screws whenever possible, using lower angle tilt lateral views (15 degrees to 23 degrees ) to evaluate for intra-articular placement. The styloid screw may be placed last and can then be evaluated on the PA and tilt PA views.
机译:目的:评估在远端骨锁定钢板固定过程中关节内螺钉放置的具体透视检查。方法:根据制造商的手术技术指南,在尸体前臂的radius骨上涂上固定角度的掌侧钢板。使用测角仪以各种描述的角度将样品放置在荧光镜中,包括标准后前角(PA),倾斜PA(11度),标准侧面和倾斜侧面(15度,23度,30度)视图。以数字方式分别捕获每个螺钉并以各种组合的放射线图像。结果:仅倾斜PA视图正确显示所有4个螺钉是关节外的。在标准的PA视图上,2个尺骨螺钉出现在关节内。较低角度的倾斜侧视图(15度和23度)正确显示了尺骨螺钉,但不是茎突螺钉。最高角度侧视图(30度)可以正确看到径向螺钉,但不能看到乙状(多数尺骨)螺钉。茎突螺钉似乎在每个侧视图上都在关节内,除了在30度外,并且在PA和倾斜PA视图上均可以正确看到。结论:在锁定vol骨远端ar骨钢板的过程中,需要多个斜视图来评估关节内螺钉的放置。较小的角度倾斜侧面视图更适用于尺骨螺钉,而较大的角度视图则更适用于径向螺钉。我们建议首先尽可能放置尺骨螺钉,使用较低角度的倾斜侧视图(15度至23度)评估关节内放置的位置。茎突螺钉可以放在最后,然后可以在PA和倾斜PA视图上进行评估。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号