Two different instruments were deployed to measure hydroperoxy radical (HO2) and total peroxy radicals during May and June 2002 at a rural site located at Rock Springs near State College, Pennsylvania. One instrument was the Penn State Ground-Based Tropospheric Hydrogen Oxides Sensor (GTHOS), which measured HO2 by laser-induced fluorescence (LIF) of OH following the chemical conversion of HO2 to OH by adding NO. The other was the Peroxy Radical Chemical Ionization Mass Spectrometer (PerCIMS) instrument that provided HO2 (HO2 mode) or total peroxy radicals (HOxROx mode) measurements. The two instruments were compared by exchanging calibration sources and by side-by-side ambient measurements. Excellent agreement was obtained in the calibration comparisons with the slope of a correlation plot close to 1.0 and a small intercept. Daily HO2 measurements from GTHOS and PerCIMS (in HO2 mode) on 4 days show that diurnal variations normally agreed to within about 40%. A comparison of HO2 measured by GTHOS and HOxROx measured by PerCIMS shows good correlation for both average diurnal variation and individual diurnal cycles. On average, HO2 from GTHOS was about 0.66 times the HOxROx from PerCIMS, meaning that organic peroxy radicals account for about one third of the total peroxy radicals in this environment. [References: 34]
机译:在2002年5月至6月期间,在宾夕法尼亚州立学院附近的Rock Springs的一个农村站点中,部署了两种不同的仪器来测量氢过氧自由基(HO2)和总过氧自由基。一种仪器是宾州州立地面对流层氢氧传感器(GTHOS),该传感器通过添加NO将HO2化学转化为OH后,通过OH的激光诱导荧光(LIF)测量HO2。另一台是过氧自由基化学电离质谱仪(PerCIMS),可提供HO2(HO2模式)或总过氧自由基(HOxROx模式)测量。通过交换校准源和并排的环境测量来比较这两种仪器。在校正比较中获得了极好的一致性,相关图的斜率接近1.0,截距很小。 GTHOS和PerCIMS(以HO2模式)在4天的每日HO2测量结果表明,日变化通常在约40%之内。通过GTHOS测量的HO2和通过PerCIMS测量的HOxROx的比较显示,平均日变化和单个日周期均具有良好的相关性。平均而言,来自GTHOS的HO2约为来自PerCIMS的HOxROx的0.66倍,这意味着有机过氧自由基约占该环境中总过氧自由基的三分之一。 [参考:34]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号