Validation of a new non-invasive portable tonometer for determining arterial pressure wave and pulse wave velocity: the PulsePen device.

机译:用于确定动脉压力波和脉搏波速度的新型无创便携式眼压计的验证:PulsePen设备。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

OBJECTIVE: To validate a new, small portable tonometer (PulsePen) that is able to assess carotid artery pressure and to measure pulse wave velocity (PWV) non-invasively. Its software provides absolute arterial pressure values, an assessment of arterial pulse wave contours, an estimation of reflection waves and measurements of PWV. DESIGN AND METHODS: Two validation studies were carried out. The aim of the first study was to compare arterial pressure values and pulse wave contours recorded in the carotid artery using the PulsePen versus intra-arterial simultaneous measurements in 10 patients undergoing cardiac catheterization. The pulse wave contour was assessed using Fourier analysis. The comparison between the two methods showed no difference in arterial pressure wave spectral moduli from harmonics 1 to 6. The second study compared PWV measurements taken with the PulsePen (one tonometer) and measurements performed with two Millar tonometers in 68 subjects (32 men, 36 women). PulsePen measurements wererealized as two consecutive measurements in the carotid and femoral arteries, both synchronized by electrocardiogram. The pulse wave transit time was calculated as the difference between the time delay of the femoral pulse wave and the carotid pulse wave in relation to the R wave of the electrocardiogram. These measurements were compared with PWV obtained by simultaneous carotid and femoral measurements with the two Millar tonometers. No difference between the two methods was found, with a variation coefficient of 7.7%. The variation coefficients of the inter-observer and intra-observer reproducibility for the PulsePen were 7.9 and 7.2%, respectively. CONCLUSIONS: These results show that the PulsePen enables an easy and reliable evaluation of central arterial pressure and stiffness in clinical ambulatory practice, especially in high-risk patients in whom arterial stiffness has been shown to be a significant indicator of morbidity and mortality.
机译:目的:验证一种新型的小型便携式眼压计(PulsePen),该压力计能够评估颈动脉压并无创地测量脉搏波速度(PWV)。其软件提供了绝对的动脉压值,动脉脉搏波轮廓评估,反射波估算和PWV测量。设计与方法:进行了两项验证研究。第一项研究的目的是比较10例接受心脏导管插入术的患者使用PulsePen与动脉内同时测量所记录的颈动脉中的动脉压值和脉搏波轮廓。使用傅立叶分析评估脉搏波轮廓。两种方法的比较显示,从谐波1到谐波6,动脉压力波频谱模量没有差异。第二项研究比较了使用PulsePen(一个眼压计)进行的PWV测量和使用两个Millar眼压计进行的68位受试者(32位男性,36岁)的测量结果女人)。 PulsePen测量实现为颈动脉和股动脉的两个连续测量,均通过心电图同步。脉搏波传播时间计算为相对于心电图的R波的股脉搏波和颈动脉脉搏波之间的时间差。将这些测量结果与通过两个Millar眼压计同时进行颈动脉和股骨测量获得的PWV进行比较。两种方法之间没有发现差异,变异系数为7.7%。 PulsePen的观察者间和观察者内再现性的变异系数分别为7.9%和7.2%。结论:这些结果表明,PulsePen能够在临床门诊实践中轻松,可靠地评估中心动脉压和僵硬度,尤其是对于那些已显示动脉僵硬度是发病率和死亡率的重要指标的高危患者而言。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号