Fifteen years of ozonesonde measurements at McMurdo Station, Antarctica (78°S), are used to test the ability of the SLIMCAT off-line 3-D chemical transport model to reproduce Antarctic stratospheric ozone in the period of August–October over many annual cycles. Two versions of SLIMCAT, both previously used in Arctic studies, are used in a detailed quantitative comparison for total column ozone and ozone mixing ratios (O3MR) at the vertical resolution of SLIMCAT. The newer model run, EC, forced by ERA-40 ECMWF meteorological (re)analyses, uses a general circulation model (GCM) radiation scheme to derive vertical transport and has improved chemistry and denitrification. The older run, UK, uses UKMO analyses and the MIDRAD scheme. Run EC shows good agreement with measured total column ozone (within ±10%). Run UK has similar agreement except during the annual ozone depletion period when run UK overestimates total column ozone by ~20% in many years. Linear regression of O3MR shows run EC is in excellent agreement with measurements, R2 = 0.89. Run UK does not agree as well at higher altitudes in late winter. Overall, the newer version of SLIMCAT, with improved vertical velocity due to the use of the GCM radiation scheme and improved vertical and temporal resolution due to the use of ERA-40 ECMWF (re) analyses, does well in reproducing variations in Antarctic ozone concentrations over many annual cycles, indicating SLIMCAT can make useful contributions to chemistry climate models (CCM).
机译:在南极麦克默多站(78°S)进行了十五年的臭氧探空仪测量,用于测试SLIMCAT离线3-D化学传输模型在许多年度周期内的8月至10月期间重现南极平流层臭氧的能力。 。先前在北极研究中都使用过的两种版本的SLIMCAT,用于在SLIMCAT的垂直分辨率下对总塔臭氧和臭氧混合比(O3MR)进行详细的定量比较。在ERA-40 ECMWF气象(再)分析的推动下,较新的模型运行EC使用通用循环模型(GCM)辐射方案得出垂直传输,并改善了化学性质和反硝化作用。英国的较早版本使用UKMO分析和MIDRAD方案。运行EC与测得的总色谱柱臭氧(在±10%以内)显示出良好的一致性。英国运行公司也有类似的协议,除了在每年的臭氧消耗期期间,英国运行公司多年来一直高估了总色谱柱臭氧量约20%。 O3MR的线性回归表明,运行EC与测量值非常吻合,R2 = 0.89。冬季晚些时候,Run UK在较高的海拔上也不太同意。总体而言,较新版本的SLIMCAT具有较高的垂直速度(由于使用了GCM辐射方案),并且由于使用了ERA-40 ECMWF(重新)分析而提高了垂直和时间分辨率,在再现南极臭氧浓度的变化方面表现出色在许多年度周期中,这表明SLIMCAT可以为化学气候模型(CCM)做出有益的贡献。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号