...
首页> 外文期刊>Journal of Geophysical Research, D. Atmospheres: JGR >Accuracy assessment and correction of Vaisala RS92 radiosonde water Accuracy assessment and correction of Vaisala RS92 radiosonde water
【24h】

Accuracy assessment and correction of Vaisala RS92 radiosonde water Accuracy assessment and correction of Vaisala RS92 radiosonde water

机译:维萨拉RS92探空仪水的准确性评估和校正维萨拉RS92探空仪水的准确性评估和校正

获取原文
获取原文并翻译 | 示例

摘要

Relative humidity (RH) measurements from Vaisala RS92 radiosondes are widely used in research and operational applications, but their accuracy is not well characterized as a function of height, RH, and time of day (or solar altitude angle). This study compares RS92 RH measurements to simultaneous water vapor measurements from three reference instruments of known accuracy. Cryogenic frost point hygrometer measurements are used to characterize the RS92 accuracy above the 700-mbar level, microwave radiometer measurements characterize the RS92 accuracy averaged over essentially the lower troposphere, and the RS92 accuracy at the surface is characterized by a system of 6 RH probes with National Institute of Standards and Technology–traceable calibrations. The three RS92 accuracy assessments are combined to yield a detailed estimate of RS92 accuracy for all RH conditions from the surface to the lowermost stratosphere. An empirical correction is derived to remove the mean bias error, yielding corrected RS92 measurements whose bias uncertainty is independent of height or RH and is estimated to be ±4% of the measured RH value for nighttime soundings and ±5% for daytime soundings, plus an RH offset uncertainty of ±0.5% RH that is significant for dry conditions. The accuracy of an individual RS92 sounding is further characterized by the 1-a "random production variability," estimated to be ±1.5% of the measured RH value. The daytime bias correction must be used with caution, as it is only accurate for clear-sky or near-clear conditions owing to the complicated effect of clouds on the solar radiation error.
机译:维萨拉RS92探空仪的相对湿度(RH)测量被广泛用于研究和操作应用中,但其精度并不能很好地表征为高度,相对湿度和时间(或太阳高度角)的函数。这项研究将RS92 RH测量与来自三台已知精度的参考仪器的同时进行的水蒸气测量进行了比较。低温霜点湿度计的测量值用于表征700毫巴以上的RS92精度,微波辐射计的测量值用于表征对流层下部平均的RS92精度,并且表面的RS92精度由6个RH探头组成,美国国家标准技术研究院–可追溯的校准。结合了三个RS92准确性评估,可以得出从表面到平流层最低的所有RH条件的RS92准确性的详细估计。导出经验校正以消除平均偏差误差,得出校正后的RS92测量值,其偏差不确定度与高度或RH无关,并且估计为夜间测深的RH值的±4%,白天测深的RH值的±5%。 RH偏移不确定度为±0.5%RH,这对于干燥条件非常重要。单个RS92探测的准确度进一步以1-a“随机产生变异性”为特征,估计为测得的RH值的±1.5%。白天偏差校正必须谨慎使用,因为由于云对太阳辐射误差的复杂影响,该偏差仅在晴朗天空或接近晴朗的条件下才是准确的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号