A new medical device to assist the introduction of ambulatory 24-h pH-metry probe.

机译:一种新的医疗设备,可协助引入动态24小时pH测量探头。

获取原文
获取原文并翻译 | 示例
           

摘要

Oesophageal manometry (OM) and ambulatory 24-h oesophageal pH-metry (OP) are the techniques for clinical investigation of gastro-oesophageal reflux disease (GORD) . These procedures require nasal intubation, and are generally not tolerated by patients . The optimal catheter should be small enough in diameter, flexible and biocompatibleso that intubation is easily performed and that the catheter is comfortable for the patient during the study. We evaluated introduction-time (IT) and patient satisfaction (PS) during the introduction of the pH-probe after OM with a new medical device, a polyethylene mini-overtube (MOT), length of 30 cm, bent with a cord of 20 cm, with an inner diameter of 13 Fr and an outer diameter of 14.5 Fr. One hundred patients were enrolled and randomised into two groups: the control group performed with the typical intubation method (50 patients; 27 females and 23 males; mean age 52.6 +- 15.7 years) and the MOT group performed with the mini-overtube (50 patients; 29 females and 21 males; mean age 53.8 +- 15.6 years). OMs were performed using a six lumen, water-perfused OM catheter made of PVC and with a maximum diameter of 4 mm (12 Fr) (BioengineeringLaboratories s.p.a.; Cantu, CO); 24-h OP-monitoring was performed using a glass electrode (diameter of 1.5 mm) connected to a portable digital memory unit (LoT 142; MettlerToledo, M.I.C., Champagne au Mont D'Or; France). Before the OM study, MOT was placed on the manometric probe at its distal extremity. Firstly to extract manometric probe, the MOT was advanced on to overtake, for some centimetres, the upper oesophageal sphincter (UOS). When the OM-probe was extracted, the OP-probe was inserted using the MOT as a guide.
机译:食道测压(OM)和24小时动态食道pH测度(OP)是用于胃食管反流病(GORD)临床研究的技术。这些手术需要鼻腔插管,患者一般不接受。最佳导管的直径应足够小,具有柔韧性和生物相容性,以便易于进行插管并且在研究期间使患者感到舒适。我们在OM后使用新的医疗设备,长度为30 cm,用20根软线弯曲的聚乙烯微型外套管(MOT)引入pH探针期间评估了引入时间(IT)和患者满意度(PS)厘米,内径为13 Fr,外径为14.5Fr。一百例患者被随机分为两组:对照组采用典型的插管方法(50例;女性27例,男性23例;平均年龄52.6±15.7岁); MOT组采用微型套管法(50例)患者;女性29例,男性21例;平均年龄53.8±15.6岁。使用由PVC制成的,最大内径为4 mm(12 Fr)的六腔水灌注OM导管进行OMs(BioengineeringLaboratories s.p.a .; Cantu,CO);使用连接到便携式数字存储单元(LoT 142; MettlerToledo,M.I.C.,Champagne au Mont D'Or;法国)的玻璃电极(直径为1.5mm)执行24小时OP监视。在进行OM研究之前,将MOT放在末端的测压探头上。首先提取测压探头,然后将MOT推进至超过几厘米的食管上括约肌(UOS)。提取OM探针后,以MOT为指导插入OP探针。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号