首页> 外文期刊>Digestive and liver disease: official journal of the Italian Society of Gastroenterology and the Italian Association for the Study of the Liver >Prospective, randomized, pathologist-blinded study of disposable alligator-jaw biopsy forceps for gastric mucosal biopsy.
【24h】

Prospective, randomized, pathologist-blinded study of disposable alligator-jaw biopsy forceps for gastric mucosal biopsy.

机译:对胃黏膜活检的一次性鳄鱼皮钳活检钳进行的前瞻性,随机,病理学家盲研究。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND: Endoscopic biopsy forceps differ in the size and shape of the biopsy cup and the presence or absence of a needle. METHODS: We compared four different large cup gastric antral and corpus biopsy were obtained with each. Parameters examined included: weight (mg), length (mm), orientation (poor, good), intactness (1, 2, or 3 pieces), depth (superficial, above muscularis mucosae, included muscularis mucosae), crush artefact (yes, no), and overall adequacy (inadequate, suboptimal, adequate). RESULTS: Twenty-four patients were enrolled (191 biopsies). The median length was approximately 5mm (range 1.1-8.2mm). Histologically inadequate specimens were present in 4% with the forceps without needle compared to 16% of those with needles (P=0.061) and there were significantly fewer specimens in three or more pieces than did the forceps with needles 2.1% vs. 12.6% (P<0.05). CONCLUSIONS: Current alligator style forceps provide a high proportion of acceptable specimens with only minor differences between brands. Forceps from one source were least preferred by endoscopy assistants and had the highest rates of inadequate biopsies and biopsies with crush artefact. Forceps without needles provide histologically acceptable samples slightly more frequently than those with needles.
机译:背景:内窥镜活检钳在活检杯的大小和形状以及是否存在针头方面有所不同。方法:我们比较了分别获得的四种不同的大杯胃窦和胃活检。检查的参数包括:重量(mg),长度(mm),方向(差,好),完整性(1、2或3件),深度(表面,粘膜粘膜之上,包括粘膜粘膜),挤压物(是,否),以及总体上是否足够(不充分,次优,足够)。结果:二十四例患者入组(191例活检)。中位长度约为5mm(范围为1.1-8.2mm)。在组织学上不充分的标本中有无针的钳子为4%,而有针的钳子为16%(P = 0.061),三件或更多件的标本明显少于有针的钳子,分别为2.1%和12.6%( P <0.05)。结论:目前的鳄鱼夹钳提供了可接受的标本比例很高,品牌之间的差异很小。内镜助手最不希望使用一种来源的镊子,并且其活检和穿刺假体不足的活检率最高。没有针头的镊子比带有针头的镊子提供组织学上可接受的样本的频率稍高。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号