首页> 外文期刊>Journal of electromyography and kinesiology: Official journal of the International Society of Electrophysiological Kinesiology >Absolute and relative intrasession reliability of surface EMG variables for voluntary precise forearm movements
【24h】

Absolute and relative intrasession reliability of surface EMG variables for voluntary precise forearm movements

机译:表面肌电图变量的绝对和相对会间可靠性,用于主动精确的前臂运动

获取原文
获取原文并翻译 | 示例
           

摘要

The reliability of surface electromyography (EMG) derived parameters is of high importance, but there is distinct lack of studies concerning the reliability during dynamic contractions. Especially Amplitude, Fourier and Wavelet parameter in conjunction have not been tested so far. The interpretation of the EMG variables might be difficult because the movement itself introduces additional factors that affect its characteristics. The aim of this study was to determine the relative and absolute intrasession reliability of electromyographic (EMG) variables of selected arm muscles during concurrent precise elbow extension/flexion movements at different force levels and movement speed. Participants (all-male: n = 17, range 20-32 years) were asked to adapt to a gross-motor visuomotor tracking task (elbow extension/flexion movement) using a custom-built lever arm apparatus. After sufficient adaptation surface electromyography was used to record the electrical activity of mm. biceps brachii, brachioradialis and triceps brachii, and the signal amplitude (RMS [mu V]) and the mean frequency of the power spectrum (MNF [Hz]) were computed. Additionally Wavelet analysis was used. Relative reproducibility (intraclass correlation) for signal amplitude, mean frequency of the power spectrum and Wavelet intensity during dynamic contractions was fair to good, independent of force level and movement speed (ICC = 0.71-0.98). The amount of absolute intrasession reliability (coefficient of variation) of EMG variables depends on muscle and force level. (C) 2015 Elsevier Ltd. All rights reserved.
机译:表面肌电图(EMG)派生参数的可靠性非常重要,但是关于动态收缩过程中可靠性的研究显然缺乏。到目前为止,尤其是振幅,傅立叶和小波参数结合在一起尚未进行测试。 EMG变量的解释可能很困难,因为机芯本身会引入其他影响其特性的因素。这项研究的目的是确定在不同的力量水平和运动速度下同时进行的精确肘部伸展/屈曲运动过程中,选定手臂肌肉的肌电图(EMG)变量的相对和绝对术中可靠性。要求参与者(全男性:n = 17,年龄在20-32岁之间)使用定制的杠杆臂设备来适应大运动量运动的跟踪任务(肘部伸展/屈曲运动)。充分适应后,使用表面肌电图记录mm的电活动。计算肱二头肌,肱肱肌和肱三头肌,并计算信号幅度(RMS [mu V])和功率谱的平均频率(MNF [Hz])。另外,使用小波分析。动态收缩期间信号幅度,功率谱的平均频率和小波强度的相对可重复性(类内相关性)相当好,与力水平和运动速度无关(ICC = 0.71-0.98)。 EMG变量的绝对术中可靠度(变异系数)取决于肌肉和力量水平。 (C)2015 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号