首页> 外文期刊>Journal of electromyography and kinesiology: Official journal of the International Society of Electrophysiological Kinesiology >Impact of the method of exposure in total hip arthroplasty on balancing ability in response to sudden unidirectional perturbation in the first six months of the postoperative period
【24h】

Impact of the method of exposure in total hip arthroplasty on balancing ability in response to sudden unidirectional perturbation in the first six months of the postoperative period

机译:术后前六个月全髋关节置换术暴露方法对突然单向扰动的平衡能力的影响

获取原文
获取原文并翻译 | 示例
           

摘要

Introduction and objective: Total hip arthroplasty affects 3-5% of the elderly population. Therefore, the effectiveness of surgery and the ensuing rehabilitation is of great significance. This study investigated balancing ability in response to sudden unidirectional perturbation changes during the first 6. months of the postoperative period with respect to different methods of joint exposure during the operation (antero-lateral, direct-lateral and posterior to preserve the joint capsule). Our hypothesis is that the results may provide a tool to improve the rehabilitation procedures. Materials and methods: The dynamic balancing ability of 25 patients with direct-lateral exposure, 22 with antero-lateral exposure and 25 with posterior exposure during a total hip arthroplasty was examined using ultrasound-based provocation tests prior to and at 6. weeks, 12. weeks and 6. months after total hip arthroplasty. The control group was represented by 45 healthy subjects of identical age. The dynamic balancing ability after unidirectional perturbation was characterised by Lehr's damping ratio calculated from the results of tests performed with the patient standing on both limbs, standing on the affected limb and standing on the non-affected limb. Results: In the case of direct-lateral and antero-lateral exposure, Lehr's damping ratio significantly decreased compared to the preoperative values at 6. weeks postoperatively, but it increased steadily afterwards. Lehr's damping ratio while standing on the affected limb was significantly lower - even at 6. months postoperatively - than that of the control group. In the case of posterior exposure, Lehr's damping ratio continuously increased in the postoperative period and corresponded to that of the control group at 6. months after total hip arthroplasty. Discussion and conclusion: For patients operated on using direct-lateral and antero-lateral exposure methods, the dynamic balancing ability continuously improved in the first 6. months of the postoperative period, but the dynamic balancing ability of the affected limb differed from that of the control group. In the case of posterior exposure to preserve the joint capsule the dynamic balancing ability evaluated a more rapidly compared to the other two exposure methods. There was no significant difference in the balancing ability of the control group at 6. months after total hip arthroplasty with posterior exposure. The increasing range of joint motion, muscle development, and the development of the dynamic balancing ability should be taken into account when compiling rehabilitation protocols. Differences related to the method of exposure should be considered when developing the dynamic balancing ability and abandoning therapeutic aids.
机译:简介和目的:全髋关节置换术影响了3-5%的老年人口。因此,手术的有效性和随之而来的康复具有重要意义。这项研究调查了在术后最初六个月中,针对手术中关节暴露的不同方法(前外侧,前外侧和后部以保留关节囊)应对突然单向扰动变化的平衡能力。我们的假设是,结果可能提供改善康复程序的工具。材料和方法:在第6周和第12周时,采用基于超声的激发试验检查了25例直接全髋关节置换术,22例前外侧暴露和25例后暴露的动态平衡能力。全髋关节置换术后第。周零6个月。对照组由45名相同年龄的健康受试者代表。单向摄动后的动平衡能力的特征是雷尔的阻尼比,该阻尼比是根据患者站立在两肢,患肢和未患肢上的测试结果计算得出的。结果:在直接外侧和前外侧暴露的情况下,Lehr的阻尼比与术后6周的术前值相比明显降低,但此后稳定增加。站立在患肢上时,Lehr的阻尼比(甚至在术后6个月时)显着低于对照组。在后暴露的情况下,Lehr的阻尼比在术后期间持续增加,并在全髋关节置换术后6个月与对照组相对应。讨论和结论:对于采用直接外侧和前外侧暴露方法进行手术的患者,动态平衡能力在术后最初的6个月中持续提高,但是患肢的动态平衡能力与肢体的动态平衡能力有所不同。控制组。在后暴露以保护关节囊的情况下,与其他两种暴露方法相比,动态平衡能力的评估速度更快。全髋关节置换术后后暴露6个月时,对照组的平衡能力没有显着差异。编制康复方案时,应考虑到关节运动,肌肉发育和动态平衡能力的发展范围的增加。在发展动态平衡能力和放弃治疗辅助手段时,应考虑与接触方法有关的差异。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号