As for thin walled cylindrical liquid storage tanks in nuclear power plants, the current elastic design guideline against seismic loading might result in too conservative component design. Therefore, it is thought possible to make the design procedure more reasonable by taking dynamic response reduction into account. Experiments using scaled models as well as numerical analyses were carried out, and seismic behavior of thin walled cylindrical liquid storage tanks was simulated to investigate energy absorption capacity and seismic resistance of those tanks. Based on the test and analysis results, assessment procedure for buckling considering post-buckling behavior has been proposed.
机译:对于核电站中的薄壁圆柱形液体储罐,当前针对地震载荷的弹性设计准则可能会导致组件设计过于保守。因此,认为可以通过考虑动态响应降低来使设计过程更加合理。进行了使用比例模型的实验以及数值分析,并模拟了薄壁圆筒形液体储罐的抗震性能,以研究这些储罐的能量吸收能力和抗震性。基于测试和分析结果,提出了考虑屈曲后行为的屈曲评估程序。