OBJECTIVE: To evaluate the efficacy and tolerability of nonpenetrating filtering surgery augmented with implant (NPFSI) compared with nonpenetrating filtering surgery without implant (NPFS) in the treatment of patients with open angle glaucoma. METHODS: Pertinent studies were selected through extensive searches of the Cochrane Library, PubMed, Embase, and American Association of Ophthalmology (AAO) and Association for Research in Vision and Ophthalmology (ARVO) meeting abstracts. Seven controlled clinical trials meeting the predefined criteria were systematically reviewed by meta-analysis. The main outcome measures were percentage intraocular pressure (IOP) reduction, complete success rates, and qualified success rates. The pooled estimates were carried out in RevMan version 4.2 software. RESULTS: The weighted mean difference of the percentage IOP reduction from baseline were 6.7% (95% confidence intervals: -3.8 to 17.2) when comparing NPFSI with NPFS. NPFSI was associated with numerically greater, butnonsignificant, IOP lowering efficacy than NPFS. The pooled risk differences comparing NPFSI with NPFS were 0.13 (-0.02 to 0.28) in complete success rate and 0.09 (-0.04 to 0.21) in qualified success rate. Numerically greater, but nonsignificant, proportions of NPFSI patients than NPFS patients achieved the target end point IOP. NPFSI resulted in the same incidences of postoperative complications as NPFS. CONCLUSIONS: NPFSI was associated with equivalent efficacy to standard NPFS in lowering IOP. Comparable proportions of patients reached the IOP target with NPFSI and NPFS. Both surgeries were well tolerated.
机译:目的:评估非植入性非穿透性滤过手术(NPFSI)与非植入性非穿透性滤过手术(NPFS)相比开角型青光眼的疗效和耐受性。方法:通过对Cochrane图书馆,PubMed,Embase和美国眼科协会(AAO)和视觉与眼科研究协会(ARVO)会议摘要的广泛搜索,选择相关研究。荟萃分析系统地回顾了七项符合预定标准的对照临床试验。主要结果指标是降低眼内压(IOP)百分比,完全成功率和合格成功率。汇总估算值在RevMan 4.2版软件中进行。结果:将NPFSI与NPFS进行比较,眼压降低相对于基线的百分比的加权平均差为6.7%(95%置信区间:-3.8至17.2)。与NPFS相比,NPFSI在数值上与IOP降低的功效更大,但无统计学意义。比较NPFSI和NPFS的汇总风险差异是完全成功率是0.13(-0.02至0.28),合格成功率是0.09(-0.04至0.21)。 NPFSI患者的比例在数值上大于NPFS患者,但无统计学意义,达到了目标终点IOP。 NPFSI导致的术后并发症发生率与NPFS相同。结论:NPFSI在降低眼压方面与标准NPFS具有等效疗效。使用NPFSI和NPFS达到IOP目标的患者比例相当。两种手术均耐受良好。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号