首页> 外文期刊>Journal of glaucoma >Angle assessment by eyecam, goniophotography, and gonioscopy
【24h】

Angle assessment by eyecam, goniophotography, and gonioscopy

机译:通过摄像头,角度摄影和测角镜进行角度评估

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: To compare EyeCam (Clarity Medical Systems, Pleasanton, CA) and goniophotography in detecting angle closure, using gonioscopy as the reference standard. METHODS: In this hospital-based, prospective, cross-sectional study, participants underwent gonioscopy by a single observer, and EyeCam imaging and goniophotography by different operators. The anterior chamber angle in a quadrant was classified as closed if the posterior trabecular meshwork could not be seen. A masked observer categorized the eyes as per the number of closed quadrants, and an eye was classified as having angle closure if there were 2 or more quadrants of closure. Agreement between the methods was analyzed by κ statistic and comparison of area under receiver operating characteristic curves (AUC). RESULTS: Eighty-five participants (85 eyes) were included, the majority of whom were Chinese. Angle closure was detected in 38 eyes (45%) with gonioscopy, 40 eyes (47%) using EyeCam, and 40 eyes (47%) with goniophotography (P=0.69 in both comparisons, McNemar test). The agreement for angle closure diagnosis (by eye) between gonioscopy and the 2 imaging modalities was high (κ=0.86; 95% Confidence Interval (CI), 0.75-0.97), whereas the agreement between EyeCam and goniophotography was not as good (κ=0.72; 95% CI, 0.57-0.87); largely due to lack of agreement in the nasal and temporal quadrants (κ=0.55 to 0.67). The AUC for detecting eyes with gonioscopic angle closure was similar for goniophotography and EyeCam (AUC 0.93, sensitivity=94.7%, specificity=91.5%; P>0.95). CONCLUSIONS: EyeCam and goniophotography have similarly high sensitivity and specificity for the detection of gonioscopic angle closure.
机译:目的:比较将EyeCam(美国加利福尼亚州普莱森顿市的Clarity Medical Systems公司)和goniophotography公司在以角膜镜检查为参考标准检测角度闭合性方面的比较。方法:在这项基于医院的前瞻性横断面研究中,参与者由一名观察员进行了角膜镜检查,并由不同的操作员进行了EyeCam成像和眼底照相术。如果看不到后小梁网,则象限中的前房角分类为闭合。戴面具的观察者根据闭合象限的数量对眼睛进行分类,如果存在2个或更多闭合象限,则将眼睛分类为具有闭角。通过κ统计分析方法之间的一致性,并比较接收器工作特征曲线(AUC)下的面积。结果:包括八十五名参与者(85眼),其中大多数是中国人。用角膜镜检查法发现38眼(45%),用EyeCam检查40眼(47%)和使用goniophotography检查40眼(47%)闭角(两个比较,P = 0.69,McNemar测试)。角膜镜检查法和2种成像方式之间通过眼部诊断闭角的协议很高(κ= 0.86; 95%置信区间(CI)为0.75-0.97),而EyeCam和goniophotography之间的协议并不那么好(κ = 0.72; 95%CI,0.57-0.87);很大程度上是由于鼻象限和颞象限不一致(κ= 0.55至0.67)。检角术和闭孔测角术检测眼睛的AUC与测角术和EyeCam相似(AUC 0.93,灵敏度= 94.7%,特异性= 91.5%; P> 0.95)。结论:EyeCam和goniophotography具有同样高的灵敏度和专一性,用于检测角度镜的角度闭合。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号