...
首页> 外文期刊>Journal of glaucoma >Correlation between pupil diameter and angle configuration in the dark room provocative test.
【24h】

Correlation between pupil diameter and angle configuration in the dark room provocative test.

机译:在暗室激发试验中,瞳孔直径和角度配置之间的相关性。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: To study the associations between changes in pupil diameter and in the anterior chamber angle configuration during the dark room provocative test. METHODS: The study included 70 suspects of primary angle closure (study group) and 40 normal participants (control group). Using anterior-segment optical coherence tomography (AS-OCT), we measured the anterior chamber angle configuration and pupil diameter at 3 minutes and at 1.5 hours of dark adaptation. RESULTS: In the study group, the mean number of closed angle segments was significantly (P<0.001) higher at 3 minutes of dark adaptation (3.9 +/- 2.3) than at room light conditions (2.6 +/- 2.2) or at 1.5 hours of dark adaptation (3.1 +/- 2.1), with no statistically significant (P>0.05) difference between the 2 latter values. In the study group, the pupil diameter was significantly associated with the number of closed angle segments at 3 minutes of dark adaptation (P<0.01), but not at 1.5 hours of dark adaptation (P=0.13). Defined as an increased number of closed angle segments, the dark room test was positive in a significantly higher number of participants at 3 minutes than at 1.5 hours of dark adaptation [44 (63%) eyes vs. 31 (44%) eyes; P<0.05]. Final interocular pressure was statistically better correlated with the angle configuration segments assessed at 3 minutes (correlation coefficient r2=0.33) than at 1.5 hours of dark adaptation (r2=0.21). CONCLUSIONS: After short-term dark adaptation of 3 minutes, the assessment of the anterior chamber angle configuration by AS-OCT is more reliable than as if carried out after a long-term dark adaptation and may be used to identify suspects of primary angle closure.
机译:目的:研究在暗室激发试验中瞳孔直径变化与前房角构型之间的关系。方法:该研究包括70名原发性闭角患者(研究组)和40名正常参与者(对照组)。使用前段光学相干断层扫描(AS-OCT),我们在3分钟和1.5小时的暗适应下测量了前房角构型和瞳孔直径。结果:在研究组中,在黑暗适应3分钟(3.9 +/- 2.3)时,平均闭角节数显着(P <0.001)比在室内光照条件下(2.6 +/- 2.2)或1.5时高小时的暗适应时间(3.1 +/- 2.1),后两个值之间没有统计学上的显着差异(P> 0.05)。在研究组中,在黑暗适应3分钟时,瞳孔直径与闭合角段的数量显着相关(P <0.01),但在黑暗适应1.5小时时,瞳孔直径与闭合角段的数量无关(P = 0.13)。定义为闭角节段的数量增加,暗室试验在3分钟的参与者中阳性反应的阳性率明显高于1.5小时的暗适应[44(63%)眼与31(44%)眼; P <0.05]。最终的眼压在3分钟时(评估系数r2 = 0.33)与在黑暗适应1.5小时(r2 = 0.21)时评估的角度构型相关性更好。结论:短期暗适应3分钟后,AS-OCT评估前房角构型比长期暗适应后评估更可靠,可用于识别原发性闭角的可能性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号