首页> 外文期刊>Journal of Fluids Engineering: Transactions of the ASME >Low Field in the Vaned Diffuser of a Centrifugal Pump at Different Vane Setting Angles
【24h】

Low Field in the Vaned Diffuser of a Centrifugal Pump at Different Vane Setting Angles

机译:不同叶片设定角度的离心泵叶片式扩散器中的低场

获取原文
获取原文并翻译 | 示例
           

摘要

Particle image velocimetry (2D-PIV) has been used for the investigation of the time and phase-averaged flow field inside the vaned diffuser of a centrifugal pump operating at the best efficiency point (BEP). Pump performances and the diffuser flow field were analyzed for three different vane setting angles. It was evidenced that flow coefficient at the best efficiency point decreases with the diffuser setting angle reduction. From 2D-PIV measurements in five different blade to blade planes, spanwise averaged flow angles and velocity distribution were computed. It was evidenced an influence of the diffuser setting angle on the spanwise distribution of the flow rate and of the absolute mass averaged flow angle at impeller discharge. An overturning at the diffuser discharge was also evidenced for the two highest setting angles. 2D-PIV flow fields are presented in three different pseudosecondary planes in order to enlighten the cross flows affecting the diffuser flow field.
机译:粒子图像测速(2D-PIV)已用于研究在最佳效率点(BEP)下运行的离心泵的叶片式扩散器内的时间和相位平均流场。分析了三种不同叶片设定角的泵性能和扩散器流场。可以看出,随着扩散器设定角的减小,最佳效率点的流量系数减小。根据在五个不同叶片平面上的2D-PIV测量,计算了翼展方向的平均流角和速度分布。证明了扩压器设定角对流量的翼展方向分布和叶轮排放时的绝对质量平均流量角的影响。两个最大的设定角也证明了扩压器排放处的倾覆。 2D-PIV流场显示在三个不同的伪二次平面中,以启发影响扩散器流场的横流。