首页> 外文期刊>Journal of Failure Analysis and Prevention >Investigation into the Probable Cause of Failure of Economizer Tube of a Thermal Power Plant
【24h】

Investigation into the Probable Cause of Failure of Economizer Tube of a Thermal Power Plant

机译:火力发电厂省煤器管故障的可能原因研究

获取原文
获取原文并翻译 | 示例
       

摘要

In this investigation, we examined the probable cause of failure of a welded joint of a economizer tube of a 210 MW thermal power plant. X-ray radiography and chemical analysis along with detailed optical and scanning electron microscopic (SEM) examination of the economizer tube were carried out. It was concluded that severe blowholes, pipings, and porosity along with brittle fracture were responsible for the failure.
机译:在这项调查中,我们检查了210 MW火力发电厂节能器管的焊接接头可能发生故障的原因。进行了X射线照相和化学分析,并对省煤器管进行了详细的光学和扫描电子显微镜(SEM)检查。得出的结论是,严重的气孔,管道和孔隙率以及脆性断裂是造成故障的原因。