摘要

This article describes the results of an investigation concerning the failure of economizer tubes of a high-pressure boiler in a dual-purpose power/water cogeneration plant. The failure was observed in the form of rupturing of one tube and a macrohole or pinhole in another tube. The boiler had an operating period of 116,123 h since its inception. For approximately the first 100,000 h, the fuel for the boiler was crude oil, which was replaced by Bunker C oil. The boiler tube is fabricated from carbon steel SA 210A1. The location of the failure was determined by on-site visual inspection of the boiler. Detailed macro-and microexaminations of inner and outer scales on the tube were begun to determine the cause of the rupture. The composition of the fire- and waterside scale and ash deposited on the outer surface of the tubes was analyzed by energy-dispersive x-ray (EDX) technique. The reduction percentage of wall thickness of the tube facing inside and outside the furnace was calculated. The cause of the failure of the economizer tube appears to be H{sub}2SO{sub}4 dew-point corrosion. The relatively low temperature of feedwater lowered the tube metal temperature and promoted the condensation of H{sub}2SO{sub}4. The external deposits on the tubes, as a result of bunker oil firing, further helped to lower the tube metal temperature, thus promoting H{sub}2SO{sub}4 condensation over the deposit and subsequent corrosion of the tube wall. Recommendations are given to prevent/minimize such failures.
机译:本文介绍了有关两用电力/水热电联产厂中的高压锅炉省煤器管故障的调查结果。观察到失效的形式是一根管子破裂,而另一根管子有大孔或针孔。该锅炉自启动以来的运行时间为116,123小时。在大约最初的100,000小时内,锅炉的燃料为原油,并由Bunker C油代替。锅炉管由碳钢SA 210A1制成。故障的位置是通过对锅炉进行现场目视检查确定的。开始对试管的内部和外部水垢进行详细的宏观和微观检查,以确定破裂的原因。通过能量色散X射线(EDX)技术分析了沉积在管子外表面的火边和水边的水垢和灰分的成分。计算面向炉子内部和外部的管壁厚度的减小百分比。省煤器管的故障原因似乎是H {sub} 2SO {sub} 4露点腐蚀。相对较低的给水温度降低了管金属温度并促进了H {sub} 2SO {sub} 4的冷凝。由于燃料油的燃烧,在管子上的外部沉积物进一步帮助降低了管子金属温度,从而促进了沉积物上的H {sub} 2SO {sub} 4冷凝并随后腐蚀了管壁。提出了预防/减少此类故障的建议。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号