Data on 346 recovery boiler economizers in the USA and Canada were analyzed to determine the relationship between economizer failures and design, construction, operating and maintenance practices. The analysis shows that an order of magnitude reduction in failure frequency is possible with the mini-header design. Guidelines for specification and construction of recovery boiler economizers and a reference for operating and maintenance practices detrimental to economizers were developed in the course of the study.
机译:分析了美国和加拿大的346个回收锅炉省煤器的数据,以确定省煤器故障与设计,建造,运行和维护实践之间的关系。分析表明,采用小型接头设计可以使故障频率降低一个数量级。在研究过程中,制定了回收锅炉省煤器的规格和构造指南以及对省煤器有害的运行和维护实践的参考。