首页> 外文期刊>Journal of Failure Analysis and Prevention >Failure Analysis of Type 1.4301 Stainless Steel in a Cooling Water System
【24h】

Failure Analysis of Type 1.4301 Stainless Steel in a Cooling Water System

机译:1.4301型不锈钢在冷却水系统中的失效分析

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Pitting of Type 1.4301 stainless steel pipe in a brackish cooling water system was studied. The results showed that pitting of the Type 1.4301 stainless steel occurred when the water temperature was more than 40℃, and the introduction of Fe~(2+) or Fe~(3+) with concentrated chloride ions led to more severe corrosion in this cooling water system.
机译:研究了1.4301型不锈钢管在微咸冷却水系统中的点蚀。结果表明,当水温超过40℃时,1.4301型不锈钢出现点蚀现象,Fe〜(2+)或Fe〜(3+)与浓氯离子的引入导致腐蚀加剧。冷却水系统。