Piped water is used to remove hydration heat from concrete blocks during construction. In this paper we develop an approximate model for this process. The problem reduces to solving a one-dimensional heat equation in the concrete, coupled with a first order differential equation for the water temperature. Numerical results are presented and the effect of varying model parameters shown. An analytical solution is also provided for a steady-state constant heat generation model. This helps highlight the dependence on certain parameters and can therefore provide an aid in the design of cooling systems.
机译:在施工过程中,使用管道水去除混凝土砌块的水合热量。在本文中,我们为该过程开发了一个近似模型。问题减少到求解混凝土中的一维热方程,再加上水温的一阶微分方程。给出了数值结果,并显示了不同模型参数的影响。还提供了稳态恒定发热模型的解析解决方案。这有助于强调对某些参数的依赖性,因此可以为冷却系统的设计提供帮助。