The aim of this study was to measure root-dentin microhardness after instrumentation with two types of files and using irrigation with 2.5% sodium hypochlorite. Thirty roots were instrumented with irrigation: 10 roots had the pulp extirpated only; 10 roots were instrumented with stainless steel files, and 10 roots were instrumented with rotary nickel-titanium (NiTi) files. Additionally, five roots were extirpated only without irrigation and served as a control. The roots were sliced and root-dentin microhardness was determined at depths of 500 microm and 1000 microm from the pulp-dentin interface. Significant differences were found between the microhardness at 500 microm and 1000 microm (p < 0.001) in all groups. Instrumentation with NiTi rotary files affected dentin microhardness significantly to a lesser extent.
机译:这项研究的目的是在使用两种类型的锉刀并用2.5%次氯酸钠冲洗后,测量牙根的显微硬度。用灌溉仪器对三十个根进行了测定:十个根仅使果肉根除。用不锈钢锉锉10根,用旋转镍钛(NiTi)锉锉10根。另外,仅在不灌溉的情况下根除了五个根,并作为对照。将根切成薄片,并在距牙髓-牙本质界面500微米和1000微米的深度处确定根-牙本质微硬度。在所有组中,发现500微米和1000微米的显微硬度之间存在显着差异(p <0.001)。使用NiTi旋转锉器械对牙本质显微硬度的影响程度较小。