INTRODUCTION: An evaluation was made of the accuracy of the Root ZX apex locator (J. Morita Corp, Tokyo, Japan) in widened foramina, considering the existing controversy over this issue in the literature. METHODS: Ten single-root teeth were embedded in an alginate mold. The foramina were widened from 0.6 mm to 1.0 mm. The measurements were taken with all possible file sizes >/=#10. The statistical accuracy of the Root ZX was calculated for the different diameters and for the influence of file size. RESULTS: The accuracy of the Root ZX apex locator with a range of error of +/-0.5 mm was 87% in an apical foramen size of 0.6 mm and 84% using files size 45 or larger in an apical foramen size of 0.7 mm. With a tolerance of +/-1 mm, the accuracy was 99% in an apical foramen size of 0.6 mm, 98% using files size 45 or larger in an apical foramen size of 0.7 mm, and 95% using files size 70 or larger in an apical foramen size of 0.8 mm. In the rest, accuracy was not certain. The measurements taken with smaller files were shorter. There were no cases of overestimation of the working length. CONCLUSIONS: The Root ZX apex locator was accurate for an apical size of 0.6 mm, independently of the file size; between 0.7 to 0.8 mm, we should adjust the files to the foramen, whereas above size 0.9 mm the locator is not accurate. The results show that the accuracy of this electronic apex locator is gradually lost as the foramen widens. Considering the stable conditions of in vitro studies, our findings advise caution in clinical application of the locator.
机译:简介:考虑到文献中对该问题的现有争议,对Root ZX顶点定位器(J. Morita Corp,日本东京)在加宽孔中的准确性进行了评估。方法:将十个单根牙齿嵌入藻酸盐模具中。孔从0.6毫米扩大到1.0毫米。使用所有可能的文件大小> / =#10进行测量。针对不同的直径以及文件大小的影响,计算了Root ZX的统计精度。结果:Root ZX根尖定位器的误差范围为+/- 0.5 mm,在0.6 mm的根尖孔中,其准确度为87%,在45 mm或更大的根尖孔中,使用0.7 mm的锉刀,其准确度为84%。公差为+/- 1 mm,在0.6 mm的根尖孔中,准确度为99%,在45 mm或更大的孔中使用0.7 mm的顶孔,其准确度为98%,使用70 mm或更大的文件时为95%顶端孔的大小为0.8毫米。其余的不确定性。使用较小文件进行的测量更短。没有高估工作时间的情况。结论:Root ZX根尖定位器的根尖尺寸精确至0.6 mm,与锉刀尺寸无关。在0.7到0.8毫米之间,我们应该将锉刀调整到有孔,而在0.9毫米以上的位置,定位器是不准确的。结果表明,随着孔的扩大,这种电子根尖定位器的准确性逐渐下降。考虑到体外研究的稳定条件,我们的发现建议在定位器的临床应用中应谨慎行事。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号