首页> 外文期刊>Journal of Endodontics: Official Journal of American Association of Endodontists >Identification of a C-shaped canal system in mandibular second molars-part II: the effect of bone image superimposition and intraradicular contrast medium on radiograph interpretation.
【24h】

Identification of a C-shaped canal system in mandibular second molars-part II: the effect of bone image superimposition and intraradicular contrast medium on radiograph interpretation.

机译:下颌第二磨牙的C形管系统的识别-第二部分:骨图像叠加和放射内造影剂对X线片解释的影响。

获取原文
获取原文并翻译 | 示例
       

摘要

The purpose of this study was to investigate the effect of image superimposition from surrounding alveolar bone and intraradicular contrast medium on radiographic interpretation of a C-shaped canal system in mandibular second molars. Thirty mandibular second molars with fused roots were collected and stored in 10% formalin solution. After being scanned by microcomputed tomography and reconstructed, the buccal-lingual radiographs of each tooth were taken with or without intraradicular contrast medium and mandibular bony plates. The number of mesial and distal canals in the coronal-to-middle canal portion and the canal number in the apical 4-mm area were recorded. The buccal-lingual and three-dimensional view of reconstructed canal images were used to evaluate the accuracy of radiograph reading. The results were subjected to the Friedman and chi-square test. The results showed that without intraradicular contrast medium, the bone superimposition could decrease the accuracy of canal recognition significantly (p < 0.001), especially in the apical area. When contrast medium was in canals, the canal reading seemed not to be affected by the bone superimposition (p > 0.05). Based on these findings, the intraradicular contrast medium could increase the accuracy of canal recognition of a C-shaped canal system in mandibular second molars despite the bone image superimposition, especially in the detection of continuous C-shaped canals and the canals in the apical area.
机译:本研究的目的是研究来自周围牙槽骨和放射内造影剂的图像叠加对下颌第二磨牙中C形管系统的放射学解释的影响。收集三十根具有融合根的下颌第二磨牙,并将其储存在10%福尔马林溶液中。在通过微计算机断层扫描术进行扫描并重建之后,在有或没有放射性造影剂和下颌骨板的情况下拍摄每颗牙齿的舌舌X线照片。记录冠到中管部分的近中管和远端管的数目以及顶4-mm区域中的管的数目。重建的口腔图像的颊舌和三维视图被用来评估射线照相的准确性。对结果进行弗里德曼和卡方检验。结果表明,如果不使用根管造影剂,则骨重叠可能会显着降低根管识别的准确性(p <0.001),尤其是在根尖区域。当造影剂在运河中时,运河的读数似乎不受骨叠加的影响(p> 0.05)。基于这些发现,尽管骨图像叠加,但放射状造影剂仍可提高下颌第二磨牙中C形管系统的管识别准确性,尤其是在连续C形管和根尖区域的检测中。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号