首页> 外文期刊>Journal of endovascular therapy: an official journal of the International Society of Endovascular Specialists >Hemodynamic impact of transseptal access to the ascending aorta in a porcine model
【24h】

Hemodynamic impact of transseptal access to the ascending aorta in a porcine model

机译:在猪模型中经隔隔进入升主动脉的血流动力学影响

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose: To evaluate the hemodynamic impact of transseptal sheath access to the ascending aorta using increasing sheath diameters. Methods: Transseptal puncture was performed in 6 pigs (62±9 kg) facilitating guidewire passage across the left heart to the descending aorta to establish transseptal through-andthrough access into the ascending aorta. Hemodynamic parameters were evaluated during 6- to 16-F sheath deployments and after sheath retraction according to a standardized protocol. Fluorescent microspheres were injected for quantitative assessment of myocardial and cerebral perfusion and left-right shunting volume. Results: Cardiac output, heart rate, and central venous pressure (CVP) were stable throughout the study in all animals. The ratio between pulmonary artery pressure and mean arterial pressure was significantly higher during sheath deployment compared to after retraction (p<0.01), indicating transient mitral valve insufficiency. The ratio between left atrial pressure and CVP was significantly higher with the sheath in place (p<0.01), signaling transient left-right shunting; the hemodynamic alteration disappeared after sheath retraction. Myocardial perfusion (p=0.224), cerebral perfusion (p=0.209), and left-right shunting volume (p=0.111) were not significantly affected by the transseptal access. Conclusion: Transseptal access to the ascending aorta in a porcine model is feasible without persisting hemodynamic impairment or severe influence on myocardial or cerebral perfusion even with up to 16-F sheaths. Potential adverse effects need to be addressed before clinical use of this alternative access to the ascending aorta, aortic arch, and its side branches.
机译:目的:通过增加鞘管直径来评估经隔隔鞘进入升主动脉的血流动力学影响。方法:对6头(62±9 kg)猪进行经隔隔穿刺,以利于导线穿过左心到达降主动脉,以建立隔隔穿通通道进入升主动脉。根据标准方案,在6至16 F鞘管部署期间和鞘管收缩后评估血流动力学参数。注射荧光微球以定量评估心肌和脑的灌注以及左右分流的体积。结果:在整个研究中,所有动物的心输出量,心率和中心静脉压(CVP)均稳定。与收缩后相比,鞘管展开过程中肺动脉压力与平均动脉压之间的比率显着更高(p <0.01),表明短暂性二尖瓣关闭不全。鞘管就位时左心房压力与CVP的比率显着更高(p <0.01),表明短暂的左右分流。鞘管收缩后血流动力学改变消失。跨腔通路对心肌灌注(p = 0.224),脑灌注(p = 0.209)和左右分流量(p = 0.111)的影响不明显。结论:在猪模型中,经隔隔进入升主动脉是可行的,即使存在高达16 F的鞘管,也不会持续出现血流动力学损害或严重影响心肌或脑灌注。在临床上使用这种替代途径进入升主动脉,主动脉弓及其侧支之前,需要解决潜在的不利影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号