Objective: To evaluate the effectiveness of a polymeric flap valve-attached ureteral stent for preventing vesicoureteral reflux (VUR) in an animal model. Materials and Methods: One female Yorkshire pig was included in this study. A flap valve-attached and a conventional stent was inserted in the right and left ureters, respectively. The bladder was filled with contrast medium until the intravesical pressure reached 20cm H2O. Subsequently, simulated voiding cystourethrography (VCUG) was performed 50 times by manually compressing the suprapubic area until the intravesical pressure reached 50cm H2O. Intravenous pyelography (IVP) was performed thereafter to evaluate the urinary drainage. In addition, an in vitro durability test of the function of the flap valve was conducted under continuous hydrostatic pressure for 24h. Results: The volume of contrast medium needed to achieve an intravesical pressure of 20cm H2O was 1740mL. In the repeated simulated VCUG for the right ureter, VUR grades of 0 and I were recorded in 82.0 (n=41) and 18.0% (n=9) tests, respectively, whereas for the left ureter, grades of I, II, and III were recorded in 14.0 (n=7), 82.0 (n=41), and 4.0% (n=2), respectively. Thus, a significantly lower VUR grade was recorded for the right ureter than for the left ureter (p<0.001). In the bilateral VUR condition, the pressure for VUR occurrence was significantly greater in the right ureter than in the left ureter (p=0.007). No urinary obstruction was caused by the flap valve-attached ureteral stent according to the IVP findings. The in vitro durability test demonstrated slightly enhanced antireflux function and slightly decreased intraluminal drainage at 12h, and these findings sustained thereafter. Conclusion: A flap valve-attached ureteral stent effectively prevented VUR under conditions of elevated intravesical pressure without urinary obstruction.
机译:目的:评估附有聚合物瓣膜的输尿管支架在动物模型中预防膀胱输尿管反流(VUR)的有效性。材料和方法:本研究包括一只雌性约克夏猪。在右和左输尿管中分别插入附有瓣阀和常规支架。膀胱充满造影剂,直到膀胱内压力达到20厘米水柱。随后,通过人工压迫耻骨上区域直至膀胱内压力达到50cm H2O,进行了50次模拟排尿膀胱尿道造影(VCUG)。此后进行静脉肾盂造影(IVP)以评估尿液引流。另外,在连续的静水压力下进行了24小时的瓣阀功能的体外耐久性测试。结果:达到20cm H2O的膀胱内压力所需的造影剂体积为1740mL。在右输尿管的重复模拟VCUG中,分别在82.0(n = 41)和18.0%(n = 9)测试中记录了VUR等级0和I,而对于左输尿管,I,II和I级III分别以14.0(n = 7),82.0(n = 41)和4.0%(n = 2)记录。因此,记录到右输尿管的VUR等级明显低于左输尿管(P <0.001)。在双侧VUR情况下,右输尿管中发生VUR的压力明显大于左输尿管中的压力(p = 0.007)。根据IVP的发现,未安装瓣阀的输尿管支架未引起尿路阻塞。体外耐久性试验表明,在12h时,抗反流功能略有增强,管腔内引流略有减少,这些发现在此后得以维持。结论:附有瓣膜瓣的输尿管支架可在膀胱内压升高而无尿路阻塞的情况下有效预防VUR。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号